Evaluation of optimized compensators on a 3D planning system
- 1 October 1998
- journal article
- research article
- Published by Wiley in Medical Physics
- Vol. 25 (10) , 1837-1844
- https://doi.org/10.1118/1.598369
Abstract
A commercially available treatment planning system contains several functions that allow for the automation of missing tissue and optimized compensators, where the former retracts the bolus toward the source, and the latter attempts, by iteration, to establish a uniform dose at some user defined depth. The intent of this paper is to report on the compensators designed by the system and to compare them to those devised through conventional techniques. It is demonstrated that the system can model the dosimetric effects of compensators with a high degree of accuracy; measured and predicted doses agree to within 3%. Optimized compensators show slightly improved dose uniformity over thickness reduced compensators. Both show significantly improved uniformity over compensators that simply retract the bolus geometry. In cases where internal inhomogeneities exist, however, the dose uniformity from the optimized compensators vary by as much as 6% at the target depth. These deviations are comparable to the errors of the inhomogeneity algorithm itself. The pathlength reduction technique has been applied to both missing tissue and inhomogeneity compensation, and it has been found that for inhomogeneity compensation, the pathlength reduced compensators produce more uniform distributions than those generated by the optimization algorithm.Keywords
This publication has 14 references indexed in Scilit:
- Implementation of a three-dimensional compensation system based on computed tomography generated surface contours and tissue inhomogeneitiesMedical Physics, 1994
- Description and Evaluation of a New 3-D Computerized Treatment Planning Dose Compensator SystemMedical Dosimetry, 1994
- Missing tissue compensators: Evaluation and optimization of a commercial systemMedical Physics, 1992
- Compensators for three‐dimensional treatment planningMedical Physics, 1991
- An algorithm for design of beam compensatorsInternational Journal of Radiation Oncology*Biology*Physics, 1989
- Computer aided design and verification of megavoltage tissue compensators for oblique beamsMedical Physics, 1988
- Compensating filters for high energy x raysMedical Physics, 1982
- Improved method for the design of tissue compensatorsMedical Physics, 1981
- A method of large irregular field compensationThe British Journal of Radiology, 1974
- A Compensator for Variations in Tissue Thickness for High Energy BeamsThe British Journal of Radiology, 1959