Real‐Time 3‐Dimensional Echocardiography Evaluation of Intracardiac Masses
- 23 January 2006
- journal article
- Published by Wiley in Echocardiography
- Vol. 23 (3) , 218-224
- https://doi.org/10.1111/j.1540-8175.2006.00196.x
Abstract
The size of an intracardiac mass (vegetation, tumor, or thrombus) is an important predictor for embolic events and for response to treatment. Maximum diameter measurements from two-dimensional (2D) echocardiography are routinely used to determine mass size. However, most masses are irregularly shaped, making it difficult to accurately image or select the largest diameter. The selection of a diameter that is not truly the largest may lead to underestimation of the true size of the mass and a misrepresentation of the patients' prognosis. Three-dimensional (3D) echocardiography images the entire volume of a mass allowing for accurate measurements in multiple planes. We tested the hypothesis that measurements of the maximum diameter of a mass by 3D echocardiography are larger than those obtained by 2D echocardiography. Methods: Patients with findings of an intracardiac mass by 2D transthoracic (TTE) or transesophageal (TEE) echocardiogram were imaged using real-time three-dimensional echocardiography (RT3DE) within 24 hours. The complete mass was acquired on RT3DE. Maximum mass diameter was measured on 2D and RT3DE. Comparison of measurements between RT3DE and 2D was performed using correlation coefficients and Bland-Altman analyses. Results: In 19 masses evaluated in 17 patients, there was a strong correlation between 2D TTE and RT3DE maximum diameter measurements (R2=0.88, P < 0.01) but correlation was fair for 2D TEE (R2=0.48, P=0.02). In addition, 2D maximum diameter also correlated with 3D volumes (R2=0.72, P < 0.01 for TTE and R2=0.56, P < 0.01 for TEE). However, there was a consistent underestimation of maximum diameter measured by 2D (TTE and TEE) regardless of the size, location, and etiology of the mass. 2D TTE underestimates cardiac mass size by 24.6% (P < 0.001) compared to RT3DE and 2D TEE underestimated size by 19.8% (P=0.01). Conclusion: These findings suggest that RT3DE may be the technique of choice for the noninvasive evaluation of intracardiac mass size.Keywords
This publication has 14 references indexed in Scilit:
- Estimation of liver tumor volume using a three-dimensional ultrasound volumetric systemUltrasound in Medicine & Biology, 2003
- Usefulness of Transesophageal Three‐Dimensional Echocardiography in the Identification of Individual Segment/Scallop Prolapse of the Mitral ValveEchocardiography, 2003
- Incremental Value of Three‐Dimensional Echocardiography Over Transesophageal Multiplane Two‐Dimensional Echocardiography in Qualitative and Quantitative Assessment of Cardiac Masses and DefectsEchocardiography, 1995
- Three-dimensional echocardiography. In vivo validation for right ventricular volume and function.Circulation, 1994
- Echocardiographic assessment of patients with infectious endocarditis: Prediction of risk for complicationsJournal of the American College of Cardiology, 1991
- Three‐dimensional imaging of solid breast tumors with ultrasound: preliminary data and analysis of its possible contribution to the understanding of the standard two‐dimensional sonographic imagesUltrasound in Obstetrics & Gynecology, 1991
- Infective endocarditis, 1983–1988: Echocardiographic findings and factors influencing morbidity and mortalityJournal of the American College of Cardiology, 1990
- Prognostic significance of vegetations detected by two-dimensional echocardiography in infective endocarditisAmerican Heart Journal, 1986
- Clinical implications of large vegetations in infectious endocarditisArchives of internal medicine (1960), 1983
- Echocardiographic documentation of vegetative lesions in infective endocarditis: clinical implications.Circulation, 1980