Glucagon receptor of human liver. Studies of its molecular weight and binding properties, and its ability to activate hepatic adenylyl cyclase of non-obese and obese subjects.
Open Access
- 1 February 1985
- journal article
- research article
- Published by American Society for Clinical Investigation in Journal of Clinical Investigation
- Vol. 75 (2) , 397-403
- https://doi.org/10.1172/jci111713
Abstract
The glucagon receptor and the adenylyl cyclase system of human liver membranes were studied in six non-obese and six obese subjects who had elevated insulin and plasma glucagon levels. Analysis of specific glucagon binding by the method of Scatchard demonstrated a linear (monocomponent) plot with a dissociation constant of 2-3 nM, and the binding at low hormone concentrations was sensitive to guanosine triphosphate (GTP). The molecular weight of the glucagon receptor was 63,000 D as determined by an affinity labeling procedure and sodium dodecyl sulfate gel electrophoresis. Affinity labeling of this structure was specific for glucagon and inhibited by GTP. Glucagon stimulated the production of cyclic adenosine monophosphate (cAMP) by human membranes with half-maximal activation elicited by 6 nM hormone. The human cyclase system required GTP to facilitate an optimal glucagon response. NaF (10 mM) also activated the cyclase system and produced the same magnitude of response as maximum glucagon activation. A comparison of the liver adenylyl cyclase system of non-obese and obese subjects was made using glucagon (5 nM and 1 microM) and NaF (10 mM). No significant differences in cAMP production were noted between the two groups, regardless of the agent used to activate the enzyme. These findings agree with the glucagon binding studies that showed similar amounts of binding activity in the membranes from the two groups. Also, there was no influence of either age or sex of the subjects on the adenylyl cyclase response. In conclusion, human liver membranes contain a glucagon receptor and an adenylyl cyclase system that correspond closely to the well-studied system in animal liver. This system in human obesity is not altered by the approximately twofold elevation in plasma glucagon that occurs in this metabolic disorder.This publication has 30 references indexed in Scilit:
- Structural analysis of the hepatic glucagon receptor. Identification of a guanine nucleotide-sensitive hormone-binding region.Journal of Biological Chemistry, 1984
- Kinetics of glucagon in man: effects of starvation.Proceedings of the National Academy of Sciences, 1976
- Insulin and Glucagon Degradation by the Same EnzymeDiabetes, 1974
- A highly sensitive adenylate cyclase assayAnalytical Biochemistry, 1974
- Role of phosphodiesterase in glucagon resistance of large adipocytesJournal of Lipid Research, 1974
- Studies of glucagon resistance in large rat adipocytes: 125I-labeled glucagon binding and lipolytic capacityJournal of Lipid Research, 1974
- A rapid method for the isolation of rat liver plasma membranes using an aqueous two-phase polymer systemBiochimica et Biophysica Acta (BBA) - Biomembranes, 1973
- The glucagon-sensitive adenyl cyclase system in plasma membranes of rat liver. V. An obligatory role of guanylnucleotides in glucagon action.1971
- Radioimmunological determination of pancreatic and gut glucagon in plasmaDiabetologia, 1971
- Cleavage of Structural Proteins during the Assembly of the Head of Bacteriophage T4Nature, 1970