Universal correction procedure for electron-probe microanalysis. I. Measurement of X-ray depth distributions in solids
- 14 July 1985
- journal article
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 18 (7) , 1233-1243
- https://doi.org/10.1088/0022-3727/18/7/010
Abstract
X-ray distributions in aluminium, gold and carbon have been measured using the tracer technique. The results have been compared with calculations using the simplified Monte Carlo method of Love et al. (1977). It is concluded that the Monte Carlo model predicts too high a peak to the X-ray distribution and that the discrepancy is worse at lower overvoltage ratios. Calculated surface ionisation functions Phi (0) are, however, closer to experimental values and the general shape of the Phi ( rho z) curve is considered satisfactory. The more rigorous model of Myklebust et al. (1976) also overestimates the height of the peak in the Phi ( rho z) curve and, whilst it performs rather better than the simplified model for gold, it gives even more unrealistic data on carbon.Keywords
This publication has 3 references indexed in Scilit:
- A simple Monte Carlo method for simulating electron-solid interactions and its application to electron probe microanalysisJournal of Physics D: Applied Physics, 1977
- Backscattering of 10-100 keV electrons from thick targetsJournal of Physics D: Applied Physics, 1975
- Sur les bases physiques de l'analyse ponctuelle par spectrographie XJournal de Physique et le Radium, 1955