Arterial properties of the carotid and femoral artery in endurance-trained and paraplegic subjects
- 1 November 2000
- journal article
- research article
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 89 (5) , 1956-1963
- https://doi.org/10.1152/jappl.2000.89.5.1956
Abstract
In humans, the relationships of blood flow changes to structure, function, and shear rate of conducting arteries have not been thoroughly examined. Therefore, the purpose of this study was to investigate these parameters of the elastic-type, common carotid artery (CCA) and the muscular-type, common femoral artery (CFA) in long-term highly active and extremely inactive individuals, assuming that the impact of activity-induced blood flow changes on conduit arteries, if any, should be seen in these subjects. We examined 21 highly endurance-trained athletes (A), 10 paraplegic subjects (P), and 20 sedentary subjects (S) by means of noninvasive ultrasound. As a result, the CFA diameter and compliance were highest in A (9.7 ± 0.81 mm; 1.84 ± 0.54 mm2/kPa) and lowest in P (5.9 ± 0.7 mm; 0.54 ± 0.27 mm2/kPa) compared with S (8.3 ± 1.0 mm; 0.92 ± 0.48 mm2/kPa) with P < 0.01 among the groups. Both parameters correlated with each other ( r = 0.62; P < 0.01). Compared with A (378 ± 84 s−1; 37 ± 15 s−1) and S (356 ± 113 s−1; 36 ± 20 s−1), the peak and mean shear rates of the CFA were almost or more than doubled in P (588 ± 120 s−1; 89 ± 26 s−1). In the CCA, only the compliance and peak shear rate showed significant differences among the groups (A: 1.28 ± 0.47 mm2/kPa, 660 ± 138 s−1; S: 1.04 ± 0.27 mm2/kPa, 588 ± 109 s−1; P: 0.65 ± 0.22 mm2/kPa, 490 ± 149 s−1; P < 0.05). In conclusion, the results suggest a structural and functional adaptation in the CFA and a predominantly functional adaptation of the arterial wall properties to differences in the physical activity level and associated exercise-induced blood flow changes in the CCA. The results for humans confirm those from animal experiments. Similar shear rate values of S and P in the CFA support the hypothesis of constant shear stress regulation due to local blood flow changes in humans. On the other hand, the increased shear rate in the CFA in P indicates an at least partially nonphysiological response of the arterial wall in long-term chronic sympathectomy due to a change in local blood flow.Keywords
This publication has 27 references indexed in Scilit:
- Endothelial Dysfunction in Human DiseaseJournal of Molecular and Cellular Cardiology, 1999
- Vascular and cardiac remodeling in world class professional cyclistsAmerican Heart Journal, 1998
- Effects of Prolonged Immobilization of the Limb on Radial Artery Mechanical PropertiesHypertension, 1998
- Cardiovascular differences between sedentary and wheelchair-trained subjects with paraplegiaMedicine & Science in Sports & Exercise, 1998
- Association Between Intima-Media Thickness and Wall Shear Stress in Common Carotid Arteries in Healthy Male SubjectsCirculation, 1996
- Structural and Functional Adaptations of the Cardiovascular System by TrainingInternational Journal of Sports Medicine, 1996
- Carotid artery blood flow and middle cerebral artery blood flow velocity during physical exerciseJournal of Applied Physiology, 1996
- Changes in Blood Flow in the Common Femoral Artery Related to Inactivity and Muscle Atrophy in Individuals with Long-Standing ParaplegiaPublished by Springer Nature ,1996
- Exercise training alters endothelium-dependent vasoreactivity of rat abdominal aortaJournal of Applied Physiology, 1993
- Effect of long-term sympathectomy on the arterial wall in rabbits and ratsExperimental and Molecular Pathology, 1978