Gold‐Tip Electrodes—A New “Deep Lesion” Technology for Catheter Ablation? In Vitro Comparison of a Gold Alloy Versus Platinum–Iridium Tip Electrode Ablation Catheter
- 28 April 2005
- journal article
- research article
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 16 (7) , 770-772
- https://doi.org/10.1111/j.1540-8167.2005.40832.x
Abstract
Gold-tip electrodes. Radiofrequency (RF) catheter ablation is widely used to induce focal myocardial necrosis using the effect of resistive heating through high-frequency current delivery. It is current standard to limit the target tissue-electrode interface temperature to a maximum of 60-70 degrees C to avoid char formation. Gold (Au) exhibits a thermal conductivity of nearly four times greater than platinum (Pt-Ir) (3.17 W/cm Kelvin vs 0.716 W/cm Kelvin), it was therefore hypothesized that RF ablation using a gold electrode would create broader and deeper lesions as a result of a better heat conduction from the tissue-electrode interface and additional cooling of the gold electrode by "heat loss" to the intracardiac blood. Both mechanisms would allow applying more RF power to the tissue before the electrode-tissue interface temperature limit is reached. To test this hypothesis, we performed in vitro isolated liver and pig heart investigations comparing lesion depths of a new Au-alloy-tip electrode to standard Pt-Ir electrode material. Mean lesion depth in liver tissue for Pt-Ir was 4.33+/-0.45 mm (n=60) whereas Au electrode was able to achieve significantly deeper lesions (5.86+/-0.37 mm [n=60; P<0.001]). The mean power delivered using Pt-Ir was 6.95+/-2.41 W whereas Au tip electrode delivered 9.64+/-3.78 W indicating a statistically significant difference (P<0.05). In vitro pig heart tissue Au ablation (n=20) increased significantly the lesion depth (Au: 4.85+/-1.01 mm, Pt-Ir: 2.96+/-0.81 mm, n=20; P<0.001). Au tip electrode again applied significantly more power (P<0.001). Gold-tip electrode catheters were able to induce deeper lesions using RF ablation in vitro as compared to Pt-Ir tip electrode material. In liver and in pig heart tissue, the increase in lesion depth was associated with a significant increase in the average power applied with the gold electrode at the same level of electrode-tissue temperature as compared to platinum material.Keywords
This publication has 6 references indexed in Scilit:
- Is 8-mm More Effective Than 4-mm Tip Electrode Catheter for Ablation of Typical Atrial Flutter?Circulation, 1999
- Radio-Frequency Ablation as Treatment for Cardiac ArrhythmiasNew England Journal of Medicine, 1999
- Comparison of Gold Versus Platinum Electrodes on Myocardial Lesion Size Using Radiofrequency EnergyPacing and Clinical Electrophysiology, 1996
- Control of radiofrequency lesion size by power regulation.Circulation, 1989
- Tissue Heating During Radiofrequency Catheter Ablation: A Thermodynamic Model and Observations in Isolated Perfused and Superfused Canine Right Ventricular Free WallPacing and Clinical Electrophysiology, 1989
- The Effect of Electrode Design on the Efficiency of Delivery of Radiofrequency Energy to Cardiac Tissue In VitroPacing and Clinical Electrophysiology, 1989