Effect of loading and fracture motions on diaphyseal tibial fractures
- 1 January 1996
- journal article
- research article
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 14 (1) , 80-84
- https://doi.org/10.1002/jor.1100140114
Abstract
A computerized motion sensor was used to record the three‐dimensional components of interfragmentary motion during healing in three patients with closed, low‐energy fractures of the tibial diaphysis treated with functional braces. At the first measurement session, 2 weeks after fracture, the patients applied approximately 15 kg to the injured limb. Although this produced 1–4 mm of translation of the fragments, this was recovered when the load was removed. The maximum rotational and angulatory displacements often occurred as the patients rose from the chair with no weight applied to the limb and frequently were reduced as the 15 kg of load was applied. Under load, the maximum axial rotation was 3° and the maximum angular displacement was 1°. As with the translations, the initial rotational and angulatory positions of the fragments were recovered when the load was removed and the patient returned to the seated position. At 8 weeks, the patient applied full body weight, producing a maximum interfragmentary translation of 0.5 mm and maximum axial rotation or angulation of 0.5°. Abundant peripheral callus formed in all three fractures, and they healed by 15 weeks through typical gradual consolidation and mineralization of the callus, accompanied by a corresponding reduction in interfragmentary motions.Keywords
This publication has 16 references indexed in Scilit:
- The role of fixator frame stiffness in the control of fracture healing. An experimental studyJournal of Biomechanics, 1993
- Tibial External Fixation, Weight Bearing, and Fracture MovementClinical Orthopaedics and Related Research, 1993
- The effect of external fixation stiffness on early healing of transverse osteotomiesJournal of Orthopaedic Research, 1989
- Measurement of fracture movement in patients treated with unilateral external skeletal fixationJournal of Biomedical Engineering, 1989
- Design and performance of a fracture monitoring transducerJournal of Biomedical Engineering, 1988
- EFFECT OF CONTROLLED AXIAL MICROMOVEMENT ON HEALING OF TIBIAL FRACTURESThe Lancet, 1986
- Prefabricated functional braces for the treatment of fractures of the tibial diaphysis.Journal of Bone and Joint Surgery, 1984
- Measurement of Fracture Gap Motion in External FixationPublished by Wolters Kluwer Health ,1981
- The Three Dimensional Measurement of Tibia Fracture Motion by PhotogrammetryPublished by Wolters Kluwer Health ,1974
- The Role of Soft Tissues in the Stabilization of Tibial FracturesClinical Orthopaedics and Related Research, 1974