Mechanical Circulatory Support in Pediatric Patients with the MEDOS Assist Device
- 1 September 2005
- journal article
- research article
- Published by Wolters Kluwer Health in Asaio Journal
- Vol. 51 (5) , 498-500
- https://doi.org/10.1097/01.mat.0000178967.97093.47
Abstract
Mechanical circulatory support is successfully applied to patients with low cardiac output. The MEDOS-System provides pulsatile ventricular assistance for patients of all age groups, including neonates. We report our experience with seven consecutive pediatric patients with the MEDOS-VAD. The indication was bridge to transplantation in all patients. Mean age was 7.3 ± 6.5 years (range 0.75–16.9 years) and mean weight was 26.3 ± 21.7 kg (range 5.9–60 kg). Perioperative survival was 100%; complications occurred in six patients (86%; two cerebral embolism/bleeding, two rethoracotomy, two exchange of pump chamber due to thrombus formation after 4 and 9 days). Mean duration of support was 20.4 ± 10.8 days (range 6–38 days). Bilirubin decreased from 3.5 ± 2.6 mg/d to 2.1 ± 1.2 mg/d. Hospital mortality was three of seven patients who did not receive an organ offer in time. All patients who underwent subsequent heart transplantation (four of seven patients; 57%) were discharged from the hospital. Mechanical circulatory support with the MEDOS-System can be performed successfully in pediatric patients of any age. Secondary organ functions improve under this pulsatile circulatory assistance. Hemorrhage and thromboembolic events are the most frequent complications.Keywords
This publication has 8 references indexed in Scilit:
- Bridge‐to‐recovery from Acute Myocarditis in a 12‐year‐old ChildArtificial Organs, 2004
- Coagulation monitoring and management of anticoagulation during cardiac assist device supportThe Annals of Thoracic Surgery, 2003
- Long-Term Use of a Left Ventricular Assist Device for End-Stage Heart FailureNew England Journal of Medicine, 2001
- Tirofiban Administration Attenuates Platelet and Platelet-Neutrophil Conjugation but not Neutrophil Degranulation during In Vitro VAD CirculationAsaio Journal, 2001
- Multicenter experience with the thoratec ventricular assist device in children and adolescentsThe Journal of Heart and Lung Transplantation, 2001
- Glycoprotein IIb/IIIa Receptor Inhibitor Attenuates Platelet Aggregation Induced by Thromboxane A2 During In Vitro Nonpulsatile Ventricular Assist CirculationArtificial Organs, 2000
- Clinical Experience With the MEDOS HIA-VAD System in Infants and Children: A Preliminary ReportThe Annals of Thoracic Surgery, 1997
- In-vivo Evaluation of the “HIA-VAD”: a New German Ventricular Assist DeviceThe Thoracic and Cardiovascular Surgeon, 1994