Self-measurement of blood pressure: accuracy, patient preparation for readings, technique and equipment
- 1 June 2001
- journal article
- research article
- Published by Wolters Kluwer Health in Blood Pressure Monitoring
- Vol. 6 (3) , 133-138
- https://doi.org/10.1097/00126097-200106000-00003
Abstract
Self-measurement of blood pressure is commonly performed by those persons with hypertension and is advocated in many national hypertension guidelines. We examined accuracy of readings, patient knowledge, and preparation for readings, technique and equipment. The study was a prospective observational design. Sixty-nine hypertensive patients were recruited from a tertiary referral center and by newspaper advertisement. All patients had previously self-measured their blood pressure. The patients initially measured their blood pressure under direct supervision in a clinic using their usual preparation, technique and their own equipment. Then after a five-min rest, blood pressures were measured twice both by research nurse and the patient in an alternating sequence. The nurse used a standardized blood pressure measurement technique. Inadequate patient knowledge and performance of measurement technique and inaccurate equipment was common. The average initial patient systolic reading prior to the five-minute rest was higher than that of the trained nurse (9.1 ± 13 mmHg systolic, p < 0.001 and 1.5 ± 8.0 mmHg diastolic, p = 0.12). Almost half (42%) of the initial patient blood pressure readings differed in classification of hypertension/normotension from the nurse. The difference between the patient and nurse readings after the five-min rest was 3.8 ± 11.8 / 1.1 ± 6.8 mmHg. Care must be taken in interpreting patient self-measured blood pressure unless there has been adequate training and assessment of patient and equipment accuracy. Studies of health care professionals reveal similar problems therefore widespread efforts to standardize blood pressure measurement are necessary.Keywords
This publication has 22 references indexed in Scilit:
- Guidelines for the use of self-blood pressure monitoringJournal Of Hypertension, 2000
- Is usual measurement of blood pressure meaningful?Blood Pressure Monitoring, 1999
- Blood pressure screening, management and control in EnglandJournal Of Hypertension, 1998
- Treatment of Hypertension on the Basis of Home MeasurementsJapanese Circulation Journal, 1998
- The sixth report of the Joint National Committee on prevention, detection, evaluation, and treatment of high blood pressureArchives of internal medicine (1960), 1997
- Prevalence of Hypertension in the US Adult PopulationHypertension, 1995
- Alerting reaction and rise in blood pressure during measurement by physician and nurse.Hypertension, 1987
- Reasons for failure of antihypertensive treatment.BMJ, 1983
- Procedures and Discrepancies of Blood Pressure Measurements in Two Community Health CentersMedical Care, 1982