Reliability of CO2 measurements from the airway by a pharyngeal catheter in unintubated, spontaneously breathing subjects
- 1 July 1995
- journal article
- Published by Wiley in Acta Anaesthesiologica Scandinavica
- Vol. 39 (5) , 637-642
- https://doi.org/10.1111/j.1399-6576.1995.tb04141.x
Abstract
Although several short communications have appeared describing attempts to record the concentrations of carbon dioxide (CO2) from the unintubated airway by a catheter placed in the nose, so far only few reports have documented the reliability of the method. To evaluate the reliability of CO2 measurements by a catheter in the open, unintubated airway during spontaneous respiration, a 12 CH PVC catheter was forwarded through the nostril to the hypopharynx and connected to a capnograph in nine healthy volunteers. Another capnograph was connected to a tightly fitting face mask and simultaneous CO2 recordings were attained from the two parts of the airway during normoventilation, hyperventilation and rebreathing. A corresponding blood sample was drawn from the radial artery for blood gas analysis. The configurations of the capnograms recorded from the pharyngeal catheter were similar to those recorded from the face mask. The results were analysed by a multifactor analysis of variance. The carbon dioxide tension (pCO2) was significantly influenced by degree of ventilation (PPP=0.030) and interaction subject‐ventilation (P=0.015). In spite of the significant influence of the measurement site, the difference between end tidal carbon dioxide tension (PCO2(ET)) and carbon dioxide tension in arterial blood (PCO2(a)) was small. The mean differences between paired measurements (pCO2(ET)‐pCO2(a)) were ‐0.10 kPa±0.41 kPa (mean±SD) for the catheter and ‐0.20 kPa ±0.43 kPa for the face mask. The study demonstrates that reliable recordings of CO2 concentrations during spontaneous respiration can be obtained by a thin catheter positioned in the hypopharynx.Keywords
This publication has 20 references indexed in Scilit:
- Ventilation and carboxen dioxideActa Anaesthesiologica Scandinavica, 1993
- An evaluation of the Brüel and Kjær monitor 1304Anaesthesia, 1992
- A Single-blind Study of Combined Pulse Oximetry and Capnography in ChildrenAnesthesiology, 1991
- Monitoring of tidal carbon dioxide in spontaneously breathing patients using a mainstream analysing monitorAnaesthesia, 1991
- Relationship between arterial carbon dioxide and end-tidal carbon dioxide when a nasal sampling port is usedJournal of Clinical Monitoring and Computing, 1990
- Capnography in mechanically ventilated patientsCritical Care Medicine, 1988
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- Value of Nocturnal Monitoring of Transcutaneous O2 and CO2 Pressures in Adults with Respiratory FailureRespiration, 1985
- Transcutaneous PCO2 monitoring on adult patients in the ICU and the operating roomCritical Care Medicine, 1981