Communication and sampling rate limitations in IMRT delivery with a dynamic multileaf collimator system
- 21 February 2002
- journal article
- Published by Wiley in Medical Physics
- Vol. 29 (3) , 412-423
- https://doi.org/10.1118/1.1449496
Abstract
The delivery of an intensity modulated radiation field with a dynamic multileaf collimator (MLC) requires precise correlation between MLC positions and cumulative monitor units (MUs). The purpose of this study is to investigate the precision of this correlation as a function of delivered MUs and dose rate. A semi-Gaussian shaped intensity profile and a simple geometric intensity pattern consisting of four square segments were designed to deliver a total of 1, 4, 16, 64, and 100 MUs at three different dose rates of 100, 400, and 600 MU/min. The semi-Gaussian intensity pattern was delivered using both sliding window and step and shoot techniques. The dose profiles of this intensity pattern were measured with films. The four square intensity pattern was delivered using step and shoot and conventional delivery techniques for comparison. Because of geometrical symmetry, the dose to each segment in this intensity pattern is expected to be the same when the same MU is assigned to each segment. An ionization chamber was used to measure the dose in the center of each of the four square segments. For the semi-Gaussian shaped profile, significant artifacts were observed when the profile was delivered with small MUs and/or at a high dose rate. For the four square intensity pattern, the dose measured in each segment presented a large variation when delivered with small MUs and a high dose rate. The variation increases as the MU/segment decreases and as the dose rate increases. These MU and dose rate dependencies were not observed when the intensity pattern was delivered using a conventional delivery technique. The observed distortion of the semi-Gaussian profile and dose variations among the segments of the four square intensity pattern are explained by considering the sampling rate and the communication time lag between the control systems. Finally, clinical significance is discussed.Keywords
This publication has 16 references indexed in Scilit:
- Minimizing static intensity modulation delivery time using an intensity solid paradigmInternational Journal of Radiation Oncology*Biology*Physics, 1999
- Conformal radiation treatment of prostate cancer using inversely-planned intensity-modulated photon beams produced with dynamic multileaf collimationInternational Journal of Radiation Oncology*Biology*Physics, 1996
- Dosimetric evaluation of the conformation of the multileaf collimator to irregularly shaped fieldsInternational Journal of Radiation Oncology*Biology*Physics, 1995
- Field shaping for three-dimensional conformal radiation therapy and multileaf collimationSeminars in Radiation Oncology, 1995
- Dose calculation for photon beams with intensity modulation generated by dynamic jaw or multileaf collimationsMedical Physics, 1994
- Dynamic X-ray compensation for conformal radiotherapy by means of multi-leaf collimationRadiotherapy and Oncology, 1994
- X-ray field compensation with multileaf collimatorsInternational Journal of Radiation Oncology*Biology*Physics, 1994
- Combining multileaf fields to modulate fluence distributionsInternational Journal of Radiation Oncology*Biology*Physics, 1993
- Characterization of a multileaf collimator systemInternational Journal of Radiation Oncology*Biology*Physics, 1993
- The generation of intensity-modulated fields for conformal radiotherapy by dynamic collimationPhysics in Medicine & Biology, 1992