SPI/INTEGRAL in-flight performance
Open Access
- 17 November 2003
- journal article
- letter
- Published by EDP Sciences in Astronomy & Astrophysics
- Vol. 411 (1) , L91-L100
- https://doi.org/10.1051/0004-6361:20031501
Abstract
The SPI instrument has been launched on-board the INTEGRAL observatory on October 17, 2002. SPI is a spectrometer devoted to the sky observation in the 20 keV–8 MeV energy range using 19 germanium detectors. The performance of the cryogenic system is nominal and allows to cool the 19 kg of germanium down to 85 K with a comfortable margin. The energy resolution of the whole camera is 2.5 keV at 1.1 MeV. This resolution degrades with time due to particle irradiation in space. We show that the annealing process allows the recovery of the initial performance. The anticoincidence shield works as expected, with a low threshold at 75 keV, reducing the GeD background by a factor of 20. The digital front-end electronics system allows the perfect alignement in time of all the signals as well as the optimisation of the dead time (12%). We demonstrate that SPI is able to map regions as complex as the galactic plane. The obtained spectrum of the Crab nebula validates the present version of our response matrix. The 3σ sensitivity of the instrument at 1 MeV is ph cm-2 s-1 keV-1 for the continuum and ph cm-2 s-1 for narrow lines.Keywords
All Related Versions
This publication has 14 references indexed in Scilit:
- SPI instrumental background characteristicsAstronomy & Astrophysics, 2003
- SPI/INTEGRAL observation of the Cygnus regionAstronomy & Astrophysics, 2003
- INTEGRAL/SPI ground calibrationAstronomy & Astrophysics, 2003
- Calibration of the spectrometer aboard the INTEGRAL satellitePublished by SPIE-Intl Soc Optical Eng ,2003
- The digital front-end electronics for the space-borne INTEGRAL-SPI experiment: ASIC design, design for test strategies and self-test facilitiesIEEE Transactions on Nuclear Science, 2002
- The space-borne INTEGRAL-SPI gamma ray telescope: test and calibration campaignsIEEE Transactions on Nuclear Science, 2002
- Influence of temperature on the behaviour of INTEGRAL n-type HPGe detectors irradiated with fast neutronsNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1999
- Fast neutron-induced damage in INTEGRAL n-type HPGe detectorsNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1999
- The digital ASIC for the Digital Front End Electronics of the SPI astrophysics gamma-ray experimentIEEE Transactions on Nuclear Science, 1998
- Instrumental background in balloon-borne gamma-ray spectrometers and techniques for its reductionNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1985