Strength Characteristics and Failure Modes of Suture Patterns in Severed Goat Tendons
- 1 September 1989
- journal article
- research article
- Published by Wiley in Veterinary Surgery
- Vol. 18 (5) , 335-339
- https://doi.org/10.1111/j.1532-950x.1989.tb01095.x
Abstract
The load-to-gap formation, maximum load, gap present at maximum load, and failure mode were compared among four suture patterns: Bunnell-Mayer, modified Kessler, Mason-Allen, and simple interrupted. Sixty-four goat tendons were sutured with 2-0 monofilament polypropylene in one of the patterns and distracted at 92 cm/min with an electrohydraulic materials testing system. All tests were filmed at 40 frames/sec with an intermittent pin registered camera. The load-to-gap formation was not significantly different among the Bunnell (13.3 .+-. 1.5 newtons [N]), Kessler (12.8 .+-. 1.3 N), and simple interrupted (11.7 .+-. 1.7 N) patterns. The Mason-Allen pattern was significantly different (8.2 .+-. 0.5 N). The Bunnell-Mayer had the highest mean maximum load to failure (43.0 .+-. 1.6 N) followed by the modified Kessler (34.1 .+-. 1.9 N). There was no difference between the Mason-Allen (22.9 .+-. 1.4 N) and simple interrupted (21.2 .+-. 1.4 N). All of the patterns permitted at least a 1 cm gap to form when the maximum load was applied. The Bunnell pattern caused severe constriction of the tendon and failed by suture material disruption. The modified Kessler caused some focal constriction, but the suture material pulled out before breaking and sliced the tendon in the process. The Mason-Allen and the simple interrupted patterns sliced the tendon as the suture pulled out of the tendon.This publication has 16 references indexed in Scilit:
- In Vitro Comparison of the Three Loop Pulley and Locking Loop Suture Patterns for Repair of Canine Weightbearing Tendons and Collateral LigamentsVeterinary Surgery, 1986
- A Histological Evaluation of Rabbit Tendons Sutured Using the Bunnell PatternVeterinary Surgery, 1985
- American College of Veterinary Surgeons 20th Annual Meeting, February 1985Veterinary Surgery, 1985
- The Importance of Controlled Passive Mobilization on Flexor Tendon Healing:A Biomechanical StudyActa Orthopaedica, 1981
- The Pathology of Flexor Tendon RepairThe Hand, 1979
- The Locking Loop Tendon SuturePlastic and Reconstructive Surgery, 1979
- EXPERIMENTAL EVALUATION OF FACTORS AFFECTING THE STRENGTH OF TENDON REPAIRSPlastic and Reconstructive Surgery, 1977
- The microcirculation in rabbit tendon: In vivo studies after mobilisation and transectionThe Hand, 1975
- Vascular Reactions in Tendon HealingAngiology, 1970
- THE RATE OF HEALING OF TENDONS* AN EXPERIMENTAL STUDY OF TENSILE STRENGTHAnnals of Surgery, 1941