Escherichia coli: the best biological drinking water indicator for public health protection
Top Cited Papers
Open Access
- 1 December 2000
- journal article
- review article
- Published by Oxford University Press (OUP) in Journal of Applied Microbiology
- Vol. 88 (S1) , 106S-116S
- https://doi.org/10.1111/j.1365-2672.2000.tb05338.x
Abstract
Public health protection requires an indicator of fecal pollution. It is not necessary to analyse drinking water for all pathogens. Escherichia coli is found in all mammal faeces at concentrations of 10 log 9−1, but it does not multiply appreciably in the environment. In the 1890s, it was chosen as the biological indicator of water treatment safety. Because of method deficiencies, E. coli surrogates such as the ‘fecal coliform’ and total coliforms tests were developed and became part of drinking water regulations. With the advent of the Defined Substrate Technology in the late 1980s, it became possible to analyse drinking water directly for E. coli (and, simultaneously, total coliforms) inexpensively and simply. Accordingly, E. coli was re‐inserted in the drinking water regulations. E. coli survives in drinking water for between 4 and 12 weeks, depending on environmental conditions (temperature, microflora, etc.). Bacteria and viruses are approximately equally oxidant‐sensitive, but parasites are less so. Under the conditions in distribution systems, E. coli will be much more long‐lived. Therefore, under most circumstances it is possible to design a monitoring program that permits public health protection at a modest cost. Drinking water regulations currently require infrequent monitoring which may not adequately detect intermittent contamination events; however, it is cost‐effective to markedly increase testing with E. coli to better protect the public's health. Comparison with other practical candidate fecal indicators shows that E. coli is far superior overall.Keywords
This publication has 22 references indexed in Scilit:
- Chlorine Inactivation of Escherichia coli O157:H7Emerging Infectious Diseases, 1999
- Evaluating plant performance with endosporesJournal AWWA, 1996
- Comparing Defined‐Substrate Coliform Tests for the Detection of Escherichia coli in WaterJournal AWWA, 1992
- Comparing Three Sampling Designs for Monitoring Coliforms in Small Community Water SystemsJournal AWWA, 1987
- Frequency-of-Occurrence Monitoring for Coliform Bacteria in Small Water SystemsJournal AWWA, 1987
- Thermotolerant non-fecal source Klebsiella pneumoniae: validity of the fecal coliform test in recreational waters.American Journal of Public Health, 1984
- Aeromonas sobria in chlorinated drinking water suppliesMicrobial Ecology, 1982
- Behaviour in a river and dam of coliform bacteria with transferable or non-transferable drug resistanceWater Research, 1975
- The detection of various bacteria indicative of water pollution by a presence–absence (P–A) procedureCanadian Journal of Microbiology, 1969
- Biochemical and engineering aspects of sanitary water supplyJournal of the Franklin Institute, 1915