Porous titanium‐nickel for intervertebral fusion in a sheep model: Part 1. Histomorphometric and radiological analysis1
- 3 January 2003
- journal article
- research article
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 64B (2) , 107-120
- https://doi.org/10.1002/jbm.b.10530
Abstract
Porous titanium‐nickel (PTN) implants represent an alternative to traditional intervertebral fusion cages. Indeed, PTN materials possess interconnecting pores with cell capillarity properties that may promote bone ingrowth and intervertebral fusion without the need for bone grafting. In this study, a PTN intervertebral fusion device was compared to a conventional TiAlV cage packed with autologous bone in a sheep model. The two devices were implanted at two noncontiguous intervertebral lumbar sites for 3, 6, and 12 months. PTN osseointegration showed a time‐dependent trend increasing from 21.4% to 37.6% (3–12 months), whereas TiAlV cages remained at the same level of bone ingrowth (22.7%–25.4%; 3–12 months). Furthermore, PTN bone apposition (10.9%–24.2%; 3–12 months) was significantly higher than that of TiAlV implants (1.1%–5.1%; 3–12 months; p < 0.001, ANOVA). Radiological fusion scores increased with postsurgery time regardless of material type, but were consistently superior for PTN (12.5–18.5; 3–12 months) than for TiAlV cages (2.0–15.0; 3–12 months; p < 0.001, ANOVA). Implant materials were not significantly different according to the radiological interbody index based on preoperative disc height: Interbody index began at 132.6% (PTN) and 123.5% (TiAlV) immediately after surgery, then declined to 80.8% (PTN) and 91.0% (TiAlV) after 12 months. Nevertheless, ungrafted PTN constituted an excellent substrate for osteogenic cell integration and represents a new osteoconductive biomaterial with improved fusion characteristics in comparison to conventional TiAlV cages. © 2003 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 64B: 107–120, 2003Keywords
This publication has 48 references indexed in Scilit:
- Lumbar Interbody Fusion Using the Brantigan I/F Cage for Posterior Lumbar Interbody Fusion and the Variable Pedicle Screw Placement SystemSpine, 2000
- Treatment of Peri‐Implant Defects With Combination Growth Factor CementThe Journal of Periodontology, 2000
- Biomechanical Role of the Intervertebral Disc and Costovertebral Joint in Stability of the Thoracic SpineSpine, 1999
- Arthrodèse intersomatique par l'intermédiaire d'un bloc titane Plasmapore. Étude expérimentale mécanique et histologique chez la brebisChirurgie, 1999
- Are Sheep Spines a Valid Biomechanical Model for Human Spines?Spine, 1997
- Point of ViewSpine, 1994
- A Method for Histological Preparation of Undecalcified Bone Sections Containing Acrylic Bone CementBiotechnic & Histochemistry, 1991
- The Results of Early Clinical Trials with a Microporous Coated Metal Hip ProsthesisPublished by Wolters Kluwer Health ,1982
- The Optimum Pore Size for the Fixation of Porous-Surfaced Metal Implants by the Ingrowth of BoneClinical Orthopaedics and Related Research, 1980
- Biomechanical investigations of bone-porous carbon and porous metal interfacesJournal of Biomedical Materials Research, 1973