Measurement of Particle Size Characteristics of Metered Dose Inhaler (MDI) Aerosols
- 1 January 1991
- journal article
- review article
- Published by Mary Ann Liebert Inc in Journal of Aerosol Medicine
- Vol. 4 (3) , 251-263
- https://doi.org/10.1089/jam.1991.4.251
Abstract
Measurement of the aerodynamic size of an aerosol allows a prediction of its deposition efficiency and behaviour in the lung. The dynamics of volatile or pressurized (MDI) aerosols presents problems not encountered in the characterization of solid or liquid particles alone. For example, the data obtained in real-time sampling as opposed to measuring an aged aerosol provide a truer representation of circumstances during actual clinical use, yet this may be difficult to achieve due to propellent evaporation. A number of particle sizing systems have been developed based upon light scattering techniques and aerodynamic principles. Each method has its limitations; in general, they successfully measure the aerodynamic size distributions of MDI aerosols. Cascade impactors, the "gold standard" of the industry have the advantage that they allow analysis of drug mass as well as other tracers within the aerosol, but the process as a whole is labour intensive, with limited resolution. Highly automated laser-based systems developed over the past 10 years measure the surface characteristics of the aerosol rather than the direct measurement of mass. Because of different values obtained from various sizing systems, it is suggested that all MDI drugs be sized using cascade impactors but that parallel data be obtained using an alternative sizing system.Keywords
This publication has 16 references indexed in Scilit:
- The behaviour of regular-shaped non-spherical particles in a TSI aerodynamic particle sizerJournal of Aerosol Science, 1991
- Measurement of Particle Size Characteristics of Metered Dose Inhaler (MDI) AerosolsJournal of Aerosol Medicine, 1991
- High speed photographic analysis of aerosols produced by metered dose inhalersJournal of Pharmacy and Pharmacology, 1988
- The twin impinger: a simple device for assessing the delivery of drugs from metered dose pressurized aerosol inhalersJournal of Pharmacy and Pharmacology, 1987
- Calibration of the QCM Impactor for Stratospheric SamplingAerosol Science and Technology, 1987
- The behaviour of liquid droplet aerosols in an APS 3300Journal of Aerosol Science, 1986
- Calibration and Use of the Aerodynamic Particle Sizer (APS 3300)Aerosol Science and Technology, 1986
- Development of a systematic theory of suspension inhalation aerosols. I. A framework to study the effects of aggregation on the aerodynamic behaviour of drug particlesInternational Journal of Pharmaceutics, 1985
- Size analysis of suspension inhalation aerosols by inertial separation methodsJournal of Pharmacy and Pharmacology, 1976
- Size analysis of metered suspension pressurized aerosols with the Quantimet 720Journal of Pharmacy and Pharmacology, 1976