Internal Response Correction for Fluorescent Whole-Cell Biosensors
- 1 November 2002
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 74 (23) , 5948-5953
- https://doi.org/10.1021/ac0259008
Abstract
Whole-cell biosensors based on reporter genes are finding a variety of applications in analytical chemistry. Despite their ability to selectively recognize the analyte in a complex mixture, few applications of such sensing devices to real sample analysis are reported. This is mainly due to nonspecific effects on the biosensor response caused by components of the sample matrix and by environmental changes. To overcome this problem, a bacterial biosensor with an internal correction mechanism of the analytical response was developed by introducing an additional reporter gene that provides a reference signal of the analytical performance of the biosensor. The first reporter (GFPuv), expressed in response to the concentration of l-arabinose, provides the analytical signal; the second reporter (EYFP), constitutively expressed if a constant amount of IPTG is added to each sample, was used as an internal reference. By inducing the biosensor with varying amounts of l-arabinose and a constant amount of IPTG, it was possible to obtain a dose−response curve for l-arabinose, together with a constant production of EYFP, which allowed for a dynamic evaluation of the metabolic activity of the cell. When tested in nonoptimal conditions (e.g., in the presence of either ethanol or deoxycholic acid at toxic concentrations), the presence of the internal reference system corrected the analytical response due to nonspecific interferences.Keywords
This publication has 22 references indexed in Scilit:
- Exposing culprit organic pollutants: A reviewJournal of Microbiological Methods, 2001
- Heterogeneity of iron bioavailability on plants assessed with a whole-cell GFP-based bacterial biosensorMicrobiology, 2000
- Genetically Engineered Whole-Cell Sensing Systems: Coupling Biological Recognition with Reporter GenesChemical Reviews, 2000
- Online and in situ monitoring of environmental pollutants: electrochemical biosensing of cadmiumEnvironmental Microbiology, 2000
- Bacterial metal-resistance proteins and their use in biosensors for the detection of bioavailable heavy metalsJournal of Inorganic Biochemistry, 2000
- Biosensors and biochips: advances in biological and medical diagnosticsAnalytical and Bioanalytical Chemistry, 2000
- Cell-based biosensorsAnalytical and Bioanalytical Chemistry, 2000
- The construction and application of a lux ‐based nitrate biosensorLetters in Applied Microbiology, 1997
- Experimental evidence of the chaotic regime in a salicylate biosensorChemical Physics Letters, 1997
- News from the ASMS Fall Workshop: Time to revise EPA's MDL?Analytical Chemistry, 1997