Rapid Screening of Anabolic Steroids in Urine by Reactive Desorption Electrospray Ionization
- 5 October 2007
- journal article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 79 (21) , 8327-8332
- https://doi.org/10.1021/ac0711079
Abstract
Fast screening for anabolic steroids in whole urine is achieved by combining reactive desorption electrospray ionization (reactive DESI) and tandem mass spectrometry. Spray solutions containing hydroxylamine allow heterogeneous reactions of hydroxylamine with the carbonyl group of the steroids during the ionization process. Seven steroids, including a glycosteroid, were examined. The ion/molecule reaction adduct and the oxime formed via its dehydration were observed using reactive DESI; the protonated and sodiated forms of the ionized steroid were also observed both in reactive DESI and in DESI performed without the added hydroxylamine reagent. Paper, glass, and polytetrafluoroethylene were tested as sample substrates, but the glycosteroid was ionized intact without hydrolysis only from polytetrafluoroethylene. Limits of detection for the pure compounds were less than 1 ng, dynamic ranges were typically 2 orders of magnitude, and analysis times were just a few seconds. Concentration levels of ketosteroids in raw urine relevant to screening for sports doping (approximately 20 ng/mL) can be reached using a simple solid-phase microextraction (SPME) preconcentration step. Reactive DESI provided significant improvements in ionization efficiency of these steroids in raw undiluted urine as compared to conventional DESI; suppression effects due to the sample matrix were minimal and the urine matrix had no deleterious effect on steroid detection limits. Tandem mass spectrometry provided confirmation of analyte identification in this rapid screening process.Keywords
This publication has 28 references indexed in Scilit:
- Reactive Desorption Electrospray Ionization Linear Ion Trap Mass Spectrometry of Latest-Generation Counterfeit Antimalarials via Noncovalent Complex FormationAnalytical Chemistry, 2007
- Direct high-resolution peptide and protein analysis by desorption electrospray ionization Fourier transform ion cyclotron resonance mass spectrometryRapid Communications in Mass Spectrometry, 2006
- Ambient Eberlin reactions via desorption electrospray ionization mass spectrometryJournal of Mass Spectrometry, 2006
- Analysis of anabolic steroids in the horse: Development of a generic ELISA for the screening of 17α-alkyl anabolic steroid metabolitesThe Journal of Steroid Biochemistry and Molecular Biology, 2005
- Another designer steroid: discovery, synthesis, and detection of ‘madol’ in urineRapid Communications in Mass Spectrometry, 2005
- A facile and high yielding synthesis of 2,2,3,4,4-d5-androsterone-β-d-glucuronide—an internal standard in dope analysisSteroids, 2002
- Screening and confirmation analysis of anabolic agents in human urine by gas chromatography — hybrid mass spectrometry (high resolution — time of flight)Analytica Chimica Acta, 2001
- Direct Determination of Organic Compounds in Water at Parts-per-Quadrillion Levels by Membrane Introduction Mass SpectrometryAnalytical Chemistry, 1995
- Tandem mass spectrometry (MS/MS): a promising new analytical technique for specific component determination in complex mixturesAccounts of Chemical Research, 1980
- Mixture analysis by mass-analyzed ion kinetic energy spectrometryAnalytical Chemistry, 1976