Use of electrical impedance tomography (EIT) for the assessment of unilateral pulmonary function
- 28 January 2002
- journal article
- clinical trial
- Published by IOP Publishing in Physiological Measurement
- Vol. 23 (1) , 211-220
- https://doi.org/10.1088/0967-3334/23/1/322
Abstract
We describe a fully automatable quantification process for the assessment of unilateral pulmonary function (UPF) by means of EIT and propose a measurement protocol for its clinical implementation. Measurements were performed at the fourth and sixth intercostal levels on a first group of ten healthy subjects (5M, 5F, ages 26–48 years) to define the proper protocol by evaluating the most common postures and ventilation modes. Several off-line processing tools were also evaluated, including the use of digital filters to extract the respiratory components from EIT time series. Comparative measures were then carried out on a second group consisting of five pre-operatory patients with lung cancer (4M, 1F, ages 25–77 years) scheduled for radionuclide scanning. Results show that measurements were best performed with the subject sitting down, holding his arms up and breathing spontaneously. As regards data processing, it is best to extract Fourier respiratory components. The mean of the healthy subject group leads to a left–right division of lung ventilation consistent with literature values (47% left lung, 53% right lung). The comparative study indicates a good correlation (r = 0.96) between the two techniques, with a mean difference of (−0.4 ± 5.4)%, suggesting that the elimination of cardiac components from the thoracic transimpedance signal leads to a better estimation of UPF.Keywords
This publication has 12 references indexed in Scilit:
- Electrical impedance tomography (EIT) in applications related to lung and ventilation: a review of experimental and clinical activitiesPhysiological Measurement, 2000
- A comparison of neonatal and adult lung impedances derived from EIT imagesPhysiological Measurement, 1999
- Monitoring Regional Lung Ventilation by Functional Electrical Impedance Tomography during Assisted VentilationaAnnals of the New York Academy of Sciences, 1999
- Ventilation and perfusion imaging by electrical impedance tomography: a comparison with radionuclide scanningPhysiological Measurement, 1998
- Monitoring perioperative changes in distribution of pulmonary ventilation by functional electrical impedance tomographyActa Anaesthesiologica Scandinavica, 1998
- Influences of lung parenchyma density and thoracic fluid on ventilatory EIT measurementsPhysiological Measurement, 1998
- A parallel broadband real-time system for electrical impedance tomographyPhysiological Measurement, 1996
- Impedance imaging of lung ventilation: do we need to account for chest expansion?IEEE Transactions on Biomedical Engineering, 1996
- Quantification in multifrequency tomographyPhysiological Measurement, 1995
- A comparison of ventilatory and cardiac related changes in EIT images of normal human lungs and of lungs with pulmonary emboliPhysiological Measurement, 1994