Methods for determining the accuracy of radiostereometric analysis (RSA)
Open Access
- 1 January 2000
- journal article
- research article
- Published by Medical Journals Sweden AB in Acta Orthopaedica
- Vol. 71 (4) , 403-408
- https://doi.org/10.1080/000164700317393420
Abstract
The problem of determining the noise level in any measuring system remains urgent. Radiostereometric analysis (RSA) is a radiographic system of unique accuracy which has applications in areas where minute motions or no motion at all occurs. Examples are micromotion between endoprostheses and bone and in fracture healing. We have determined the accuracy of the RSA system as applied to a clinical series of spinal fusions, where the conditions for RSA were not optimal. Using the usual test-retest methodology on a phantom, we showed that its accuracy can be grossly overestimated in the individual case. We found considerable variations in the accuracy in the individual case, depending on the rigid-body configuration. The overall accuracy, expressed as 3-D "vectors" for rotation and translation, respectively, correlated with the condition number, a method for characterizing the marker configuration. Indeed, the condition number explained as much as 92% of the variation in overall rotation. This condition number, however, cannot be used to analyze the accuracy of one degree of freedom of rotation alone. Mathematical simulation of the accuracy in the individual case of the individual dimension, using in-house software, showed that the accuracy (95% confidence) varied between 0.4 and 4.6 degrees of rotation about the transverse axis, corresponding to a clinical stress series of extension and flexion.Keywords
This publication has 20 references indexed in Scilit:
- The Spondylolytic Vertebra and Its Adjacent SegmentSpine, 1997
- Effect of Lumbar Orthosis on Intervertebral MobilitySpine, 1992
- Influence of Spinal Immobilization on Consolidation of Posterolateral Lumbosacral FusionSpine, 1992
- Laxity and graft fixation after reconstruction of the anterior cruciate ligamentActa Orthopaedica, 1992
- Biomechanical model of the human shoulder joint—II. The shoulder rhythmJournal of Biomechanics, 1991
- Evaluation of micromotion in cemented vs uncemented knee arthroplasty in osteoarthrosis and rheumatoid arthritis: Randomized study using roentgen stereophotogrammetric analysisThe Journal of Arthroplasty, 1991
- Abnormal kinematics of the artificial knee: Roentgen stereophotogrammetric analysis of 10 Miller-Galante and five New Jersey LCS kneesActa Orthopaedica, 1991
- Measurement errors in roentgen-stereophotogrammetric joint-motion analysisJournal of Biomechanics, 1990
- Mobility of the Lower Lumbar Spine After Posterolateral Fusion Determined by Roentgen Stereophotogrammetric AnalysisSpine, 1990
- Roentgen stereophotogrammetry: Review of orthopedic applicationsActa Orthopaedica, 1989