Application of NMR Circuit for Superconducting Magnet Using Signal Averaging
- 1 June 1977
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 24 (3) , 1312-1314
- https://doi.org/10.1109/TNS.1977.4328928
Abstract
An NMR circuit was used to measure the absolute field values of Fermilab Energy Doubler magnets up to 44 kG. A signal averaging method to improve the S/N ratio was implemented by means of a Textronix Digital Processing Oscilloscope, followed by the development of an inexpensive microprocessor based system contained in a NIM module. Some of the data obtained from measuring two superconducting dipole magnets is presented.Keywords
This publication has 1 reference indexed in Scilit: