Standardization of Methods for Fluence (UV Dose) Determination in Bench-Scale UV Experiments
Top Cited Papers
- 1 March 2003
- journal article
- Published by American Society of Civil Engineers (ASCE) in Journal of Environmental Engineering
- Vol. 129 (3) , 209-215
- https://doi.org/10.1061/(asce)0733-9372(2003)129:3(209)
Abstract
Ultraviolet (UV) disinfection is now an accepted technology for inactivation of a variety of waterborne pathogens in wastewater and drinking water. However, the techniques used in much of the previous research aimed at providing information on UV effectiveness have not yet been standardized. Thus in many peer reviewed published literature, it is not clear how the UV irradiations were carried out, nor how the average fluence (or UV dose) given to the microorganisms has been determined. A detailed protocol for the determination of the fluence (UV dose) in a bench scale UV apparatus containing UV lamps emitting either monochromatic or broadband UV light was developed. This protocol includes specifications for the construction of a bench scale UV testing apparatus, methods for determination of the average irradiance in the water, details on UV radiometry, and considerations for microbiological testing. Use of this protocol will aid in standardization of bench scale UV testing and provide increased confidence ...Keywords
This publication has 19 references indexed in Scilit:
- TERMS AND DEFINITIONS IN ULTRAVIOLET DISINFECTIONProceedings of the Water Environment Federation, 2000
- Ultraviolet disinfection of marginal effluents: determining ultraviolet absorbance and subsequent estimation of ultraviolet intensityWater Environment Research, 1998
- Resolving UV photometer outputs with modeled intensity profilesWater Research, 1998
- Estimating Effective Germicidal Dose from Medium Pressure UV LampsJournal of Environmental Engineering, 1997
- Potassium Iodide as a Chemical Actinometer for 254 nm Radiation: Use of lodate as an Electron ScavengerPhotochemistry and Photobiology, 1997
- Numerical modelling of UV intensity: Application to collimated-beam reactors and continuous-flow systemsWater Research, 1997
- Comparison of three laboratory devices for UV-inactivation of microorganismsWater Science & Technology, 1995
- Potassium Ferrioxalate as Chemical Actinometer in Ultraviolet ReactorsJournal of Environmental Engineering, 1987
- Experimental Hypertension Produced by a Plastic Capsule Applied to the KidneyScience, 1950
- A STUDY OF THE BACTERICIDAL ACTION OF ULTRA VIOLET LIGHTThe Journal of general physiology, 1930