Cardiac Output In Mice Overexpressing β2‐Adrenoceptors Or With Myocardial Infarct
- 11 May 2001
- journal article
- Published by Wiley in Clinical and Experimental Pharmacology and Physiology
- Vol. 28 (5-6) , 364-370
- https://doi.org/10.1046/j.1440-1681.2001.03453.x
Abstract
SUMMARY: 1. The aims of the present study were to characterize cardiac output (CO) in transgenic mice that overexpress the β2‐adrenoceptor and to evaluate ultrasonic flowmetery for continuous CO measurement in the mouse in vivo.2. Under conditions of anaesthesia, open chest and positive ventilation, CO was determined with a transonic flowmeter at baseline and during dobutamine administration and intravenous volume loading in wild‐type mice (n = 17) and β2‐adrenoceptor transgenic (n = 9) and wild‐type mice with chronic myocardial infarct (n = 16).3. Compared with wild‐type mice, β2‐adrenoceptor transgenic mice with markedly enhanced ventricular contractility had a significantly higher CO, heart rate (HR) and maximal acceleration of aortic flow. Both dobutamine and volume loading increased CO in the two groups and higher levels of CO were measured in transgenic mice during the interventions. At baseline or during interventions, stroke volume was similar between β2‐adrenoceptor transgenic and wild‐type mice. Infarcted mice with impaired cardiac function had a significantly lower CO under basal and stress conditions.4. Thus, β2‐adrenoceptor transgenic mice revealed higher CO that was largely attributable to a significantly higher HR but not to an increase in stroke volume. Transonic flowmetery can detect differences in CO among mice in various functional states and is suitable for evaluation of cardiac functional reserve in mice in vivo by continuous monitoring of CO responses to different interventions.Keywords
This publication has 17 references indexed in Scilit:
- Functional Consequences of Altering Myocardial Adrenergic Receptor SignalingAnnual Review of Physiology, 2000
- Hypoxic pulmonary blood flow redistribution and arterial oxygenation in endotoxin-challenged NOS2-deficient miceJournal of Clinical Investigation, 1999
- Magnetic Resonance Imaging and Invasive Evaluation of Development of Heart Failure in Transgenic Mice With Myocardial Expression of Tumor Necrosis Factor-αCirculation, 1999
- Coupling of β 2 -Adrenoceptor to G i Proteins and Its Physiological Relevance in Murine Cardiac MyocytesCirculation Research, 1999
- Transthoracic Echocardiography in Models of Cardiac Disease in the MouseCirculation, 1996
- Validation of Transonic Small Animal Flowmeter for Measurement of Cardiac Output and Regional Blood Flow in the RatJournal of Cardiovascular Pharmacology, 1996
- Echocardiographic and cardiac doppler assessment of miceJournal of the American Society of Echocardiography, 1995
- Enhanced Myocardial Function in Transgenic Mice Overexpressing the β 2 -Adrenergic ReceptorScience, 1994
- Volume blood flow measurements with a transit time flowmeter: an in vivo and in vitro variability and validation studyClinical Physiology and Functional Imaging, 1993
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986