An elongated, narrow, slotted crossover surface coil provides surface localization capable of resolving in vivo 31 P NMR spectra from skin tissues. The shallow B1 field penetration achieves localization objectives while the probe length maintains signal-to-noise requirements. Dielectric and inductive losses are minimized via the crossover design (see T. L. Nagel et al., Magn. Reson. Med. 13, xxx (1990). In vivo spectra with millimeter depth resolution were acquired in 5 min at 2 T without pulse localization sequences. Preliminary 31P NMR spectra of normal and thermally injured rat skin were completed using a 25 × 3-mm slotted probe with a 3 × 2-cm surface region of excitation. Normal rat skin tissue PCr/Pi ratios ranged from 3.8 to 4.7 for 5-, 10-, and 30-γs pulse widths, while partial-and full-thickness scald injured tissues ranged from 0 to 2.8. Evaluation of a single minor partial thickness injury 1 to 5 h postburn shows evidence of a localized hypermetabolic response associated with hyperemia. Determination of bum depth and tissue viability appears feasible using: (1) PCr/Pi ratios and (2) observation of localized hypermetabolism. © 1990 Academic Press, Inc.This publication has 20 references indexed in Scilit:
- The crossover surface coil: an efficient in vivo nmr detectorMagnetic Resonance in Medicine, 1990
- Laser Doppler Flowmetry Evaluation of Burn Wound DepthJournal of Burn Care & Rehabilitation, 1989
- 31P NMR spectroscopy of the stomach by zig–zag coilMagnetic Resonance in Medicine, 1987
- NMR: Physical Principles and Current Status as a Biomedical TechniqueAnnals of the New York Academy of Sciences, 1987
- A new double-tuned probed for concurrent 1H and 31P NMRJournal of Magnetic Resonance (1969), 1985
- Depth pulse sequences for surface coils: spatial localization and T1 measurementsMagnetic Resonance in Medicine, 1984
- Depth and refocusing pulses designed for multipulse NMR with surface coilsJournal of Magnetic Resonance (1969), 1983
- Radiofrequency losses in NMR experiments on electrically conducting samplesJournal of Magnetic Resonance (1969), 1979
- The sensitivity of the zeugmatographic experiment involving human samplesJournal of Magnetic Resonance (1969), 1979
- A STANDARD ANIMAL BURNPublished by Wolters Kluwer Health ,1968