An Investigation of the Use of Geiger-Müller Photoelectron Counters in the Spectrographic Analysis of Phosphorus in Steel
- 1 April 1948
- journal article
- Published by Optica Publishing Group in Journal of the Optical Society of America
- Vol. 38 (4) , 377-383
- https://doi.org/10.1364/josa.38.000377
Abstract
For routine quantitative spectrographic analysis of phosphorus, using the line at 2136A, the Geiger-Müller photoelectron counter has certain advantages over both the photographic plate and the electron multiplier photo-tube. The construction of the counters and the methods of electrically shielding and mounting them on the Littrow spectrograph are briefly described. The adjustments of counter orientation, slit widths, and focus are discussed with reference to the analyses of ferrous alloys where good resolution is necessary. Because of the absorption of radiation by quartz at low wave-lengths, both absolute and relative intensities are dependent upon the position of the arc on the electrode surface. This effect, which results in appreciable error in the measured percentage composition of a sample, is investigated photographically and with G-M counters, and several methods of reducing the effect are discussed. The effect of temperature changes of the dispersing prism on line position is investigated and a suitable method of control is mentioned. Preliminary consideration of this direct-reading method shows that it seems possible to reduce the various errors so that the source fluctuation is the controlling factor.Keywords
This publication has 14 references indexed in Scilit:
- The Measurement of the Intensity Ratios of Spectral Lines with Electron Multiplier Photo-TubesJournal of the Optical Society of America, 1947
- Direct Reading Instrument for Spectrochemical AnalysisJournal of the Optical Society of America, 1944
- The Application of Multiplier Photo-Tubes to Quantitative Spectrochemical Analysis*Journal of the Optical Society of America, 1944
- Spectrochemical Light Source Errors and Their Compensation*Journal of the Optical Society of America, 1943
- An Investigation of the Properties and Applications of the Geiger-Müller Photoelectron Counter*Journal of the Optical Society of America, 1942
- Specifications and Testing of Spectrochemical Apparatus*Journal of the Optical Society of America, 1941
- Production, Characteristics, and Reliability of Geiger-Müller CountersPhysical Review B, 1937
- A High Speed Geiger-Counter CircuitPhysical Review B, 1936
- Über den Resteffekt bei ZählrohrenAnnalen der Physik, 1936
- On temperature and pressure regulation in prismatic spectrographsProceedings of the Royal Society of London. Series A, Containing Papers of a Mathematical and Physical Character, 1927