Abstract
We measured with a micro-O2 electrode the tissue PO2 (PtO2) in the cat carotid body (CB) to see whether it was adequately oxygenated when perfused or superfused with artificial, cell-free (c-f) solutions (pH = 7.4; temp = 35–38 degrees C). To obtain a relative measure of O2 consumption (VO2), we also measured the rate of disappearance of O2 following stoppage of the blood flow, and compared these disappearance curves with those during stoppage of the c-f perfusion solutions. In 14 cats normal (blood perfusion) PtO2 values ranged from 10 to 104 mmHG; chi = 72 +/- 4 (SE--as used throughout). During 3 h of c-f perfusion with air-equilibrated Locke's solution, PtO2 ranged from 62 to about 160 mmHg; chi = 133 +/- 4. When perfused with Fay's equilibrated with 98% O2–2% CO2 no PtO2 values in the CB were below 300 mmHg (4 cats). In eight additional cats the CB was cleared of blood then superfused with saline equilibrated with 50% O2 underneath and air-equilibrated saline over. Less than 5% of the PtO2 values found were below 5 mmHg. We conclude that most studies on the artificially perfused or superfused CB cannot be invalidated on the basis that the preparations were hypoxic. O2 disappearance curves taken during blood perfusion were significantly faster than during c-f perfusion indicating a marked reduction in VO2 with c-f perfusion.