Identifying Variables Associated With Inaccurate Self-Monitoring of Blood Glucose: Proposed Guidelines to Improve Accuracy
- 1 November 2000
- journal article
- research article
- Published by SAGE Publications in The Diabetes Educator
- Vol. 26 (6) , 981-989
- https://doi.org/10.1177/014572170002600610
Abstract
PURPOSE this study was conducted to evaluate patients' proficiency in self-monitoring of blood glucose (SMBG). METHODS Diabetes nurse educators in 4 suburban Minneapolis clinic sites surveyed the SMBG training/cure practices of 280 patients with type 1 and type 2 diabetes. Participant SMBG technique was measured by direct observation. Participants performed a finger puncture and used their own meters to measure the first blood sample. A second sample was measured on the HemoCue B Glucose analyzer, and a third sample was used to measure hemoglobin. The series of tests were then repeated. If either of the 2 glucose tests was more than 15% from the HemoCue value, participants were reeducated about the manufacturer's suggested procedure. RESULTS Of the 280 participants, 19% had blood glucose test results greater than the 15% limit for meter accuracy. After reeducation, 69% of those who had initially failed achieved acceptable results. The most significant problems were lack of periodic meter technique evaluation, difficulty using wipe meters, incorrect use of control solutions, lack of hand washing even when observed, and unclean meters. CONCLUSIONS As a result of the study, guidelines were subsequently developed to evaluate meter accuracy in an outpatient setting. Further effort is needed to establish standards for evaluating SMBG.This publication has 10 references indexed in Scilit:
- Consensus Development Conference on Diabetic Foot Wound Care: 7-8 April 1999, Boston, Massachusetts. American Diabetes Association.Diabetes Care, 1999
- Bedside glucose monitoring quality control practices - A college of American Pathologists Q-Probes study of program quality control documentation, program characteristics, and accuracy performance in 544 institutions1996
- ADVANCES AND STRATEGIES FOR GLUCOSE MONITORING1995
- American Association of Diabetes Educators White Paper on Healthcare ReformThe Diabetes Educator, 1994
- Self-Monitoring of Blood GlucoseDiabetes Care, 1994
- The Effect of Intensive Treatment of Diabetes on the Development and Progression of Long-Term Complications in Insulin-Dependent Diabetes MellitusNew England Journal of Medicine, 1993
- Self-Monitoring of Blood Glucose by Adults With Diabetes in the United States PopulationDiabetes Care, 1993
- Proposed Strategies for Reducing User Error in Capillary Blood Glucose MonitoringDiabetes Care, 1993
- An Assessment of the Effect of Haematocrit on the Hemocue Blood Glucose AnalyserAnnals of Clinical Biochemistry: International Journal of Laboratory Medicine, 1993
- Implementation of capillary blood glucose monitoring in a teaching hospital and determination of program requirements to maintain quality testingThe American Journal of Medicine, 1992