Field comparison of shallow P‐wave seismic sources near Houston, Texas
- 1 November 1994
- journal article
- Published by Society of Exploration Geophysicists in Geophysics
- Vol. 59 (11) , 1713-1728
- https://doi.org/10.1190/1.1443558
Abstract
A shallow P‐wave seismic source comparison was conducted at a site near Houston, Texas where the depth to the water table was approximately 7 m, and near‐surface materials consisted of clays, sands, and gravels. Data from twelve different sources during this November 1991 comparison are displayed and analyzed. Reflection events are interpretable at about 40 ms on some 220-Hz analog low‐cut filtered field files, and at 60 ms on most 110‐ and 220-Hz analog low‐cut filtered field files. Calculations and local water well information suggest the 40-ms event is from the top of the water table. Subsurface explosive sources seem to possess the highest dominant frequency, broadest bandwidth, and recorded amplitudes and, therefore, have the greatest resolution potential at this site. Our previous work and that of our colleagues suggests that, given a specific set of site characteristics, any source could dominate the comparison categories addressed here.Keywords
This publication has 0 references indexed in Scilit: