Clinical benefits and risk analysis of topical hemostats: a review
Top Cited Papers
- 20 October 2005
- journal article
- review article
- Published by Springer Nature in Journal of Artificial Organs
- Vol. 8 (3) , 137-142
- https://doi.org/10.1007/s10047-005-0296-x
Abstract
A variety of local hemostats including absorbable gelatin sponge, collagen hemostat, and oxidized cellulose are commercially available. Local hemostats are applied when cautery, ligature, or other conventional hemostatic method is impractical. Proper handling is essential to control bleeding and only the required amount should be used, even though the hemostat is expected to dissolve promptly. A dry local hemostat absorbs body fluid of several times its own weight and expands postoperatively. Therefore, when an absorbable hemostatic agent is retained on or near bony or neural spaces, the minimum amount should be left after hemostasis is achieved. Documentation is important with regard to the hemostat used, including the name of the agent, site, and amount. This information is used as a reference in the interpretation of postoperative diagnostic images, since retained hemostat may sometimes mimic an abscess or recurrent tumor. The antigenicity of collagen is known to be low because of homology. When the safety of collagen was evaluated, the incidence of positive reactions was reported as 3.0%, and collagen may cause allergic reactions. Minimum inflammation without strong foreign body reactions or blockade of healing is desirable after the use of local hemostats. Strong foreign body reactions, chronic inflammation, and infections can cause granuloma formation after local hemostat use. By using local hemostats, it is possible to improve the condition of the patient, reduce complications, and lower direct and indirect costs.Keywords
This publication has 70 references indexed in Scilit:
- In Vitro and In Vivo Evaluation of the Biocompatibility and Cytotoxicity of Local Hemostatic AgentsJapanese Journal of Cardiovascular Surgery, 2004
- In Vivo Evaluation of Collagen Hemostats: Biocompatibility and Resorption.Japanese Journal of Cardiovascular Surgery, 2003
- MR characteristics of oxidized cellulose (Surgicel).American Journal of Roentgenology, 1999
- Appearance of oxidized cellulose (Surgicel) on abdominal radiographs.American Journal of Roentgenology, 1996
- Histologic and immunohistochemical features in biopsy sites in which bovine collagen matrix was used for hemostasisJournal of the American Academy of Dermatology, 1996
- Appearance of oxidized cellulose (Surgicel) on postoperative CT scans: similarity to postoperative abscess.American Journal of Roentgenology, 1993
- Collagen engineering for biomaterial useClinical Materials, 1992
- In vitro Effect of a Microfibrillar Collagen Hemostat on PlateletsPathophysiology of Haemostasis and Thrombosis, 1987
- Collagen Fibers as a Fleece Hemostatic AgentPublished by Wolters Kluwer Health ,1980
- Collagen as a BiomaterialAnnual Review of Biophysics and Bioengineering, 1974