The effects of time varying intravascular signal intensity and k‐space acquisition order on three‐dimensional MR angiography image quality
- 1 July 1996
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 6 (4) , 642-651
- https://doi.org/10.1002/jmri.1880060413
Abstract
The optimum infusion timing and k-space ordering for obtaining gadolinium-enhanced three-dimensional MR angiograms was determined through computer modeling using temporal contrast characteristics obtained from patient gadolinium infusion data. The effects of bolus timing were evaluated by varying the relationship between peak intravascular gadolinium concentration and the time at which the center of k space was acquired (tck) for sequential and centric acquisition techniques. Flow phantom experiments were performed to validate the theoretical computations. Gadolinium concentration at the time of central k-space acquisition determines intravascular signal intensity. Artifacts, including vessel broadening and edge ringing, depend on the order in which k space is collected and on how rapidly the gadolinium concentration changes. Artifacts are greatest when the center of k space is acquired before the intravascular gadolinium peak. Application of the optimal infusion timing results in preferential arterial enhancement with a minimum of artifacts in patients undergoing MR angiography.Keywords
This publication has 14 references indexed in Scilit:
- Breath-hold gadolinium-enhanced MR angiography of the abdominal aorta and its major branches.Radiology, 1995
- Iliac artery MR angiography: comparison of three-dimensional gadolinium-enhanced and two-dimensional time-of-flight techniques.Radiology, 1995
- MR imaging (including MR angiography) of abdominal aortic aneurysms: comparison with conventional angiography.American Journal of Roentgenology, 1994
- Gadolinium-enhanced MR aortography.Radiology, 1994
- Spiral CT of renal artery stenosis: comparison of three-dimensional rendering techniques.Radiology, 1994
- Dynamic gadolinium‐enhanced three‐dimensional abdominal MR arteriographyJournal of Magnetic Resonance Imaging, 1993
- Normal abdominal enhancement patterns with dynamic gadolinium-enhanced MR imaging.Radiology, 1991
- Gadolinium-enhanced MR angiography.Radiology, 1990
- Bolus geometry and dynamics after intravenous contrast medium injection.Radiology, 1984
- Sodium dehydrocholate circulation times in digital subtraction angiographyAmerican Journal of Roentgenology, 1983