Mass Measurement Accuracy in Analyses of Highly Complex Mixtures Based Upon Multidimensional Recalibration
- 17 November 2006
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 78 (24) , 8374-8385
- https://doi.org/10.1021/ac0606251
Abstract
Mass spectrometry combined with a range of on-line separation techniques has become a powerful tool for characterization of complex mixtures, including protein digests in proteomics studies. Accurate mass measurements can be compromised due to variations that occur in the course of an on-line separation, e.g., due to excessive space charge in an ion trap, temperature changes, or other sources of instrument "drift". We have developed a multidimensional recalibration approach that utilizes existing information on the likely mixture composition, taking into account variable conditions of mass measurements, and that corrects the mass calibration for sets of individual peaks binned by, for example, the total ion count for the mass spectrum, the individual peak abundance, m/z value, and liquid chromatography separation time. The multidimensional recalibration approach uses a statistical matching of measured masses in such measurements, often exceeding 105, to a significant number of putative known species likely to be present in the mixture (i.e., having known accurate masses), to identify a subset of the detected species that serve as effective calibrants. The recalibration procedure involves optimization of the mass accuracy distribution (histogram), to provide a more confident distinction between true and false identifications. We report the mass accuracy improvement obtained for data acquired using a TOF and several FTICR mass spectrometers. We show that the multidimensional recalibration better compensates for systematic mass measurement errors and also significantly reduces the mass error spread: i.e., both the accuracy and precision of mass measurements are improved. The mass measurement improvement is found to be virtually independent of the initial instrument calibration, allowing, for example, less frequent calibration. We show that this recalibration can provide sub-ppm mass measurement accuracy for measurements of a complex fungal proteome tryptic digest and provide improved confidence or numbers of peptide identifications.Keywords
This publication has 38 references indexed in Scilit:
- Optimization and Use of Peptide Mass Measurement Accuracy in Shotgun ProteomicsMolecular & Cellular Proteomics, 2006
- Advances in proteomics data analysis and display using an accurate mass and time tag approachMass Spectrometry Reviews, 2006
- Multicomponent Internal Recalibration of an LC−FTICR-MS Analysis Employing a Partially Characterized Complex Peptide Mixture: Systematic and Random ErrorsAnalytical Chemistry, 2005
- Accurate mass measurements by Fourier transform mass spectrometryMass Spectrometry Reviews, 2004
- Fourier transform ion cyclotron resonance mass spectrometry: A primerMass Spectrometry Reviews, 1998
- Routine Part-per-Million Mass Accuracy for High- Mass Ions: Space-Charge Effects in MALDI FT-ICRAnalytical Chemistry, 1998
- Electrospray-ionization time-of-flight mass spectrometry in protein chemistryAnalytical Chemistry, 1994
- Open-endcap Penning traps for high precision experimentsInternational Journal of Mass Spectrometry and Ion Processes, 1989
- Experimental determination of the effects of space charge on ion cyclotron resonance frequenciesInternational Journal of Mass Spectrometry and Ion Processes, 1983
- Theory of space-charge shift of ion cyclotron resonance frequenciesInternational Journal of Mass Spectrometry and Ion Processes, 1983