Assessment of intracranial hemodynamics in carotid artery disease by transcranial Doppler ultrasound
- 1 December 1985
- journal article
- Published by Journal of Neurosurgery Publishing Group (JNSPG) in Journal of Neurosurgery
- Vol. 63 (6) , 890-898
- https://doi.org/10.3171/jns.1985.63.6.0890
Abstract
Noninvasive transcranial Doppler recordings were correlated to the angiographic findings in 77 patients with carotid artery disease. Stenoses reducing the luminal area of the internal carotid artery by 75% or more also reduced the pulsatility transmission index (PTI) of the ipsilateral middle cerebral artery (MCA). The PTI is the pulsatility index of the artery under study expressed as a percent of the pulsatility index of another intracranial artery with presumed unimpeded inflow in the same individual. For stenoses in the 75% to 89% category. PTI reduction was significantly greater in patients with bilateral carotid stenosis, indicating an impaired potential for collateral flow in these patients. The PTI reduction probably reflects both the pressure drop across the stenosis and the cerebral autoregulatory response. Two criteria proved useful in demonstrating collateral MCA supply through the circle of Willis. On the recipient side, retrograde flow in the proximal anterior cerebral artery was demonstrated in 29 of the 31 patients when this flow pattern was disclosed angiographically. In 26 of these patients, the anterior cerebral artery on the supplying side also had clearly increased flow velocity. Increased flow velocities in the proximal posterior cerebral artery were present in 26 of the 30 vessels that were acting as a collateral channel to the ipsilateral MCA.Keywords
This publication has 23 references indexed in Scilit:
- Cerebral blood flow measurement in cerebrovascular occlusive diseases.Stroke, 1984
- Dependency of Blood Flow Velocity in the Middle Cerebral Artery on End-Tidal Carbon Dioxide Partial Pressure—A Transcranial Ultrasound Doppler StudyJournal of Cerebral Blood Flow & Metabolism, 1984
- Evaluation of cerebrovascular spasm with transcranial Doppler ultrasoundJournal of Neurosurgery, 1984
- Middle cerebral artery perfusion pressure in cerebrovascular occlusive disease.Stroke, 1983
- Correlation of Clinical and Angiographic Findings in Brain Ischemia with Regional Cerebral Blood Flow Measured by the Xenon Inhalation TechniqueNeurosurgery, 1982
- Quantitation of carotid stenosis with continuous-wave (C-W) Doppler ultrasound.Stroke, 1979
- Problems of Spectrum and Bias in Evaluating the Efficacy of Diagnostic TestsNew England Journal of Medicine, 1978
- Cerebral arterial blood flow and aneurysm surgeryJournal of Neurosurgery, 1977
- Cerebral Blood Flow before and After Carotid EndarterectomyVascular Surgery, 1972
- Intraluminal Diameters of the Intracranial ArteriesVascular Surgery, 1967