Low-voltage scanning electron microscopic imaging of ultrahigh-molecular-weight polyethylene
- 1 October 1995
- journal article
- research article
- Published by Wiley in Journal of Biomedical Materials Research
- Vol. 29 (10) , 1167-1174
- https://doi.org/10.1002/jbm.820291002
Abstract
Submicron ultrahigh-molecular-weight polyethylene (UHMWPE) wear particles from total joint prostheses may contribute to implant failure through particle-mediated aseptic loosening. The purpose of this study was to examine the microstructure of virgin UHMWPE powder to determine its morphology for future comparison with wear debris. A new method of low-voltage scanning electron microscopy (LVSEM) in an oil-free vacuum was applied, which produced high-resolution images of UHMWPE micromorphology, while minimizing specimen damage and obviating the need for image processing. GUR 415 UHMWPE virgin powder particles were examined by using routine high-voltage SEM, LVSEM, and image analyses. LVSEM showed that UHMWPE particles were composed of submicron-size spherical subparticles connected by numerous nanometer-size fibrils. These spherical subparticles had a highly textured surface morphology seen only by LVSEM. Fracture of the nanometer-size fibrils was observed. Routine high-voltage SEM obfuscates the intricate and delicate UHMWPE micromorphology as well as the damage done by the accompanying high-voltage electron. This study suggests that the micromorphology of wear particles previously studied with routine high-voltage SEM was overlooked or damaged, justifies the need for LVSEM in future studies, and raises the question of what is the true morphology of polyethylene wear debris retrieved from human tissues. © 1995 John Wiley & Sons, Inc.Keywords
This publication has 10 references indexed in Scilit:
- Macrophage/particle interactions: Effect of size, composition and surface areaJournal of Biomedical Materials Research, 1994
- In vivo inflammatory response to polymethylmethacrylate particulate debris: Effect of size, morphology, and surface areaJournal of Orthopaedic Research, 1994
- Composition and morphology of wear debris in failed uncemented total hip replacementThe Journal of Bone and Joint Surgery. British volume, 1994
- Morphometric and microanalytical analyses of alumina wear particles in hip prosthesesBiomaterials, 1993
- Characterization of aluminum films on a polycarbonate substrateThin Solid Films, 1991
- Quantitative comparison of the histological effects of particulate polymethylmethacrylate versus polyethylene in the rabbit tibiaArchives of orthopaedic and trauma surgery, 1991
- Third-bodies in tribologyWear, 1990
- Friction and wear properties of polymer, metal, and ceramic prosthetic joint materials evaluated on a multichannel screening deviceJournal of Biomedical Materials Research, 1981
- The appearances of wear on polyethylene—a comparison of in vivo and in vitro wear surfacesJournal of Biomedical Materials Research, 1978
- Tissue response to implanted polymers: The significance of sample shapeJournal of Biomedical Materials Research, 1976