Suspected Aortic Dissection and Other Aortic Disorders: Multi–Detector Row CT in 373 Cases in the Emergency Setting
- 1 March 2006
- journal article
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 238 (3) , 841-852
- https://doi.org/10.1148/radiol.2383041528
Abstract
To retrospectively review the authors' experience with multi-detector row computed tomography (CT) for detection of aortic dissection in the emergency setting. The investigation was institutional review board approved, did not require informed patient consent, and was HIPAA compliant. In 373 clinical evaluations in the emergency setting, 365 patients suspected of having aortic dissection and/or other aortic disorders underwent multidetector CT. Criteria for acute aortic disorder were confirmed by using surgical and pathologic diagnoses or findings at clinical follow-up and any subsequent imaging as the reference standard. Positive cases were characterized according to type of disorder interpreted. Resulting sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy were calculated by using two-way contingency tables. All cases found to be negative for acute aortic disorders were grouped according to alternative CT findings. Sixty-seven (18.0%) of the 373 cases were interpreted as positive for acute aortic disorder. One hundred twelve acute aortic disorders were identified in these 67 cases: 23 acute aortic dissections, 14 acute aortic intramural hematomas, 20 acute penetrating aortic ulcers, 44 new or enlarging aortic aneurysms, and 11 acute aortic ruptures. Three hundred five (81.8%) cases were interpreted as negative for acute aortic disorder. In 48 negative cases, multidetector CT depicted alternative findings that accounted for the clinical presentation. Of these, three included both acute aortic disorders and alternative findings, and 45 included only alternative findings. One (0.3%) case was indeterminate for acute aortic disorder. Overall, 112 findings were interpreted as positive for acute aortic disorder, an alternative finding, or both at CT. No interpretations were false-positive, one was false-negative, 67 were true-positive, and 304 were true-negative. Sensitivity, specificity, PPV, NPV, and accuracy were 99% (67 of 68), 100% (304 of 304), 100% (67 of 67), 99.7% (304 of 305), and 99.5% (371 of 373), respectively. The positivity rate for acute aortic dissection or other acute aortic disorder in 373 cases examined at multi-detector row CT was 18.0%.Keywords
This publication has 44 references indexed in Scilit:
- Accuracy of biplane and multiplane transesophageal echocardiography in diagnosis of typical acute aortic dissection and intramural hematomaJournal of the American College of Cardiology, 1996
- Detecting Acute Thoracic Aortic Dissection in the Emergency Department: Time Constraints and Choice of the Optimal Diagnostic TestAnnals of Emergency Medicine, 1996
- CT aortography of thoracic aortic rupture.American Journal of Roentgenology, 1996
- CT of Calcified Chronic Aortic Dissection Simulating Atherosclerotic AneurysmJournal of Computer Assisted Tomography, 1993
- Rupture of the outer partition of aortic dissection during transesophageal echocardiographyThe American Journal of Cardiology, 1991
- Aortic dissectionCurrent Problems in Cardiology, 1989
- ECHOCARDIOGRAPHY IN DIAGNOSIS OF AORTIC DISSECTIONThe Lancet, 1989
- Risk factors for aortic dissection: A necropsy study of 161 casesPublished by Elsevier ,1984
- Pathogenesis of dissecting aneurysm of aortaThe American Journal of Cardiology, 1977
- Clinical Features and Prognosis in Dissecting Aneurysm of the AortaCirculation, 1967