Comparison between 2D and 3D gradient‐echo sequences for MRI of human lung ventilation with hyperpolarized 3He
- 23 August 2004
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 52 (3) , 673-678
- https://doi.org/10.1002/mrm.20164
Abstract
Images of hyperpolarized 3He were acquired during breath‐hold in four healthy volunteers with the use of an optimized 3D gradient‐echo sequence. The images were compared with existing 2D gradient‐echo methods. The average SNR from a 13‐mm‐thick slice in the peripheral lung was 1.4 times greater with 3D. In the airways the average SNR was 1.7 times greater with 3D. The higher SNR of 3D was particularly evident when regions of unimpeded gas diffusion, such as the major airways, were imaged with thin slices. This is because diffusion dephasing due to the slice‐encoding gradient is minimized with a 3D sequence. The in vivo experimental findings were substantiated with experiments on phantoms of free gas, which showed more than four times the SNR with 3D compared to 2D. Theoretical simulations of the 2D and 3D k‐space filters were also performed to predict the SNR and spatial resolution observed in the experimental images. Magn Reson Med 52:673–678, 2004.Keywords
This publication has 14 references indexed in Scilit:
- Investigating 3He diffusion NMR in the lungs using finite difference simulations and in vivo PGSE experimentsJournal of Magnetic Resonance, 2004
- Assessment and compensation of susceptibility artifacts in gradient echo MRI of hyperpolarized 3He gasMagnetic Resonance in Medicine, 2003
- Co-registration of acquired MR ventilation and perfusion images?Validation in a porcine modelMagnetic Resonance in Medicine, 2002
- MRI of the lungs using hyperpolarized noble gasesMagnetic Resonance in Medicine, 2002
- k‐Space filtering in 2D gradient‐echo breath‐hold hyperpolarized 3He MRI: Spatial resolution and signal‐to‐noise ratio considerationsMagnetic Resonance in Medicine, 2002
- Magnetic resonance hysterography and hysterosalpingography using hyperpolarized3He: Demonstration of feasibility in an animal modelJournal of Magnetic Resonance Imaging, 2000
- Quantification of Regional Intrapulmonary Oxygen Partial Pressure Evolution during Apnea by 3He MRIJournal of Magnetic Resonance, 1999
- Sensitivity and resolution in 3D NMR microscopy of the lung with hyperpolarized noble gasesMagnetic Resonance in Medicine, 1999
- Lung Air Spaces: MR Imaging Evaluation with Hyperpolarized3He GasRadiology, 1999
- Observation of Diffusion in Xenon Gas by NMRJournal of Magnetic Resonance, Series A, 1995