Cost effectiveness of the implantable cardioverter defibrillator: a preliminary analysis
- 1 August 1992
- Vol. 68 (8) , 241-245
- https://doi.org/10.1136/hrt.68.8.241
Abstract
An implantable cardioverter defibrillator (ICD) may be effective in reducing the risk of sudden cardiac death. The high cost of ICD treatment, however, compared with alternatives raises the question of whether this new technology is an efficient use of scarce health care resources. To estimate the incremental cost effectiveness of the implantable cardioverter defibrillator compared with drug treatment with amiodarone in the management of patients at high risk of sudden cardiac death. A cost effectiveness model was constructed from data already published and other secondary sources. Differences in patient survival were calculated from life tables for comparable ICD and amiodarone patient series. Costs were based on typical patient management protocols derived from current United Kingdom practice and interviews with physicians. Cost effectiveness of ICD treatment was computed over 20 years; all future costs and effects were discounted at 6% per year. Estimated life expectancy was 11.1 and 6.7 years with ICD and amiodarone respectively; the discounted 20 year difference lies in the range 1.7 to 3.7 years. Discounted 20 year treatment costs were 28,400 pounds for the ICD and 2300 pounds for amiodarone. Cost effectiveness of ICD treatment lies in the range of 15,400 pounds to 8200 pounds per life-year gained. Cost effectiveness of ICD treatment is similar to some existing cardiac programmes funded under the NHS but uncertainty exists due to limitations of the data. Costs of ICD treatment may fall in the future as the life of the device increases and less invasive implantation methods are needed. The effectivess of ICD compared with amiodarone is currently being studied by a randomised controlled trial.Keywords
All Related Versions
This publication has 20 references indexed in Scilit:
- Psychological Support and Psychiatric Management of Patients with Automatic Implantable Cardioverter DefibrillatorsThe International Journal of Psychiatry in Medicine, 1990
- Long-term follow-up of postmyocardial infarction patients with ventricular tachycardia or ventricular fibrillation treated with amiodaroneThe American Journal of Cardiology, 1990
- Life at a price: the implantable defibrillator.Heart, 1990
- Efficacy of the automatic implantable cardioverter-defibrillator in prolonging survival in patients with severe underlying cardiac diseaseJournal of the American College of Cardiology, 1990
- Benefit and risks of long-term amiodarone therapy for sustained ventricular tachycardia/fibrillation: Minimum of three-year follow-up in 145 patientsAmerican Heart Journal, 1990
- FROM THE EDITOR...Pacing and Clinical Electrophysiology, 1990
- Anxiety and Anger in Patients with Ventricular Tachyarrhythmias. Responses after Automatic Internal Cardioverter Defibrillator ImplantationPacing and Clinical Electrophysiology, 1989
- Health Care Technology: Effectiveness, Efficiency and Public PolicyCanadian Public Policy, 1988
- The structure of psychological distress and well-being in general populations.Journal of Consulting and Clinical Psychology, 1983
- Termination of Malignant Ventricular Arrhythmias with an Implanted Automatic Defibrillator in Human BeingsNew England Journal of Medicine, 1980