The field dependence of NMR imaging. II. Arguments concerning an optimal field strength
- 1 October 1986
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 3 (5) , 730-746
- https://doi.org/10.1002/mrm.1910030509
Abstract
Some of the factors involved in the choice of field strength for NMR imaging are examined. The influences of relaxation times and chemical shift upon image quality and signal‐to‐noise ratio are highlighted, and power deposition is introduced as a significant factor which may limit the flexibility and information available at higher fields as long as 180° echo pulses continue to be necessary. Chemical‐shift imaging is examined and found wanting as a means of coping with chemical‐shift artifacts, and the use of multiple echoes (albeit with research) in conjunction with multiple‐slice techniques is advocated as representing an efficient data‐gathering scheme which can improve image signal‐to‐noise ratio. With such use, a medium field strength (0.5–1 T) is presented as representing, for general purpose imaging of head and torso, the best current compromise when imaging time is of major importance, with the important caveat that new techniques may always invalidate this conclusion. © 1986 Academic Press, Inc.This publication has 12 references indexed in Scilit:
- The field dependence of NMR imaging. I. Laboratory assessment of signal‐to‐noise ratio and power depositionMagnetic Resonance in Medicine, 1986
- Estimating radiofrequency power deposition in body NMR imagingMagnetic Resonance in Medicine, 1985
- Frequency Shift Artifacts in MR ImagingJournal of Computer Assisted Tomography, 1985
- Quadrature detection in the laboratory frameMagnetic Resonance in Medicine, 1984
- The National Radiological Protection Boardad hocAdvisory Group on Nuclear Magnetic Resonance Clinical ImagingThe British Journal of Radiology, 1983
- A versatile magnetic field gradient control system for NMR imagingJournal of Physics E: Scientific Instruments, 1981
- Mapping of metabolites in whole animals by 31P NMR using surface coilsNature, 1980
- An efficient decoupler coil design which reduces heating in conductive samples in superconducting spectrometersJournal of Magnetic Resonance (1969), 1979
- The sensitivity of the zeugmatographic experiment involving human samplesJournal of Magnetic Resonance (1969), 1979
- The signal-to-noise ratio of the nuclear magnetic resonance experimentJournal of Magnetic Resonance (1969), 1976