The effect of phosphorylcholine‐coated materials on the inflammatory response and fibrous capsule formation: In vitro and in vivo observations
Open Access
- 14 November 2003
- journal article
- research article
- Published by Wiley in Journal of Biomedical Materials Research Part A
- Vol. 68A (1) , 1-9
- https://doi.org/10.1002/jbm.a.10141
Abstract
Several experiments were performed to compare the in vitro adhesion of human macrophage and granulocyte inflammatory cells to polyethylene terephthalate substrate and the same coated with a phosphorylcholine (PC)‐based polymer. The inclusion of various types of serum at different stages in the assay indicated that protein adsorption and passivation of the surface may be responsible for reducing the number of inflammatory cells adhering to the uncoated polyethylene terephthalate controls. In all of the assays performed there was a statistically significant reduction (p < 0.05; analysis of variance) of the number of inflammatory cells adhering to the PC‐coated samples, linked to the ability of these surfaces to resist protein adhesion. Implantations of PC‐coated stainless steel and high‐density polyethylene USP control samples were made in a rabbit intramuscular model. Histological examination of the number of inflammatory cells present around the implant sites 4 weeks postimplantation showed there were 40% less cells associated with the PC‐coated samples compared with control, but this was not statistically significant. Fibrous capsule thickness, however, whereas marginally less at 4 weeks, had almost completely regressed for the PC‐coated sample at 13 weeks postimplantation and was statistically thinner (p < 0.01; Mann‐Whitney U test) than the high‐density polyethylene USP control. These findings support the view that low biointeractions observed for PC‐based technology in vitro can result in reduced inflammation and foreign body reaction in vivo. © 2003 Wiley Periodicals, Inc. J Biomed Mater Res 68A: 1–9, 2004Keywords
This publication has 27 references indexed in Scilit:
- Suppression of the inflammatory response from adherent cells on phospholipid polymersJournal of Biomedical Materials Research Part A, 2003
- Adipogenic healing in adult mice by implantation of hollow devices in muscleThe Anatomical Record, 2002
- Blending in with the BodyJournal of Chemical Education, 2002
- Osseointegration on metallic implant surfaces: Effects of microgeometry and growth factor treatmentJournal of Biomedical Materials Research, 2002
- Why do phospholipid polymers reduce protein adsorption?Journal of Biomedical Materials Research, 1998
- Adsorption of Complement Protein C3 at Polymer SurfacesJournal of Colloid and Interface Science, 1996
- Adhesion and cytokine production by monocytes on poly(2‐methacryloyloxyethyl phosphorylcholine‐co‐alkyl methacrylate)‐coated polymersJournal of Biomedical Materials Research, 1995
- Complement C3 participation in monocyte adhesion to different surfaces.Proceedings of the National Academy of Sciences, 1994
- Fibrin(ogen) mediates acute inflammatory responses to biomaterials.The Journal of Experimental Medicine, 1993
- Is the Vroman effect of importance in the interaction of blood with artificial materials?Journal of Biomaterials Science, Polymer Edition, 1992