Vowel and consonant recognition of cochlear implant patients using formant-estimating speech processors
- 1 July 1987
- journal article
- research article
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 82 (1) , 48-57
- https://doi.org/10.1121/1.395436
Abstract
Vowel and consonant confusion matrices were collected in the hearing alone (H), lipreading alone (L), and hearing plus lipreading (HL) conditions for 28 patients participating in the clinical trial of the multiple-channel cochlear implant. All patients were profound-to-totally deaf and "hearing" refers to the presentation of auditory information via the implant. The average scores were 49% for vowels and 37% for consonants in the H condition and the HL scores were significantly higher than the L scores. Information transmission and multidimensional scaling analyses showed that different speech features were conveyed at different levels in the H and L conditions. In the HL condition, the visual and auditory signals provided independent information sources for each features. For vowels, the auditory signal was the major source of duration information, while the visual signal was the major source of first and second formant frequency information. The implant provided information about the amplitude envelope of the speech and the estimated frequency of the main spectral peak between 800 and 4000 Hz, which was useful for consonant recognition. A speech processor that coded the estimated frequency and amplitude of an additional peak between 300 and 1000 Hz was shown to increase the vowel and consonant recognition in the H condition by improving the transmission of first formant and voicing information.This publication has 10 references indexed in Scilit:
- Acoustic parameters measured by a formant-estimating speech processor for a multiple-channel cochlear implantThe Journal of the Acoustical Society of America, 1987
- Absolute identification of electric pulse rates and electrode positions by cochlear implant patientsThe Journal of the Acoustical Society of America, 1985
- A comparison of three speech coding strategies using an acoustic model of a cochlear implantThe Journal of the Acoustical Society of America, 1985
- Psychophysical studies evaluating the feasibility of a speech processing strategy for a multiple-channel cochlear implantThe Journal of the Acoustical Society of America, 1983
- Two-Component Hearing Sensations Produced by Two-Electrode Stimulation in the Cochlea of a Deaf PatientScience, 1983
- Psychophysical studies for two multiple-channel cochlear implant patientsThe Journal of the Acoustical Society of America, 1982
- Stop consonant place perception with single-formant stimuli: Evidence for the role of the front-cavity resonanceThe Journal of the Acoustical Society of America, 1979
- Speech-Discrimination Scores Modeled as a Binomial VariableJournal of Speech and Hearing Research, 1978
- Toward the Acoustic Specification of Australian EnglishSTUF - Language Typology and Universals, 1970
- Critical Bandwidth and the Frequency Coordinates of the Basilar MembraneThe Journal of the Acoustical Society of America, 1961