Hepatic arterial-phase dynamic gadolinium-enhanced MR imaging: optimization with a test examination and a power injector.
- 1 January 1997
- journal article
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 202 (1) , 268-273
- https://doi.org/10.1148/radiology.202.1.8988222
Abstract
To optimize findings at dynamic gadolinium-enhanced hepatic magnetic resonance imaging in the hepatic arterial phase, a timing examination was performed after injection of a 0.5-mL timing bolus of gadopentetate dimeglumine. In the experimental group (n = 28), power injection was used and the imaging delay was determined in each patient on the basis of the results of the timing examination. In the control group (n = 28), hand injection and a fixed 20-second imaging delay were used. Arterial-phase examinations (defined as relative liver enhancement of not more than 30% of peak parenchymal enhancement) were successful in 26 (93%) experimental group patients and in 17 (61%) control group patients.Keywords