Regional blood flow in canine myocardium as determined by local washout of a freely diffusible radioactive indicator
- 1 June 1979
- journal article
- research article
- Published by Wiley in Acta Physiologica Scandinavica
- Vol. 106 (2) , 115-121
- https://doi.org/10.1111/j.1748-1716.1979.tb06379.x
Abstract
The aim of this study has been to examine the utility of the washout of a freely diffusible radioactive indicator as a measure of regional myocardial blood flow in open‐chest anesthetized dogs. The method employed was direct intramyocardial injection of Xenon‐133 followed by measurement of its gamma‐radiation. The experimental washout curves show, after a short acceleration period, monoexponential washout of the indicator over two decades. We found indications of insignificant veno‐arterial shunting by diffusion of the blood flow level measured, insignificant arterial recirculation of the indicator, and minimal radioactive contribution to precordial residue versus time curves arising from right heart or non‐myocardial tissue. We suggest that diffusion equilibrium between the tissue in the counting field and the blood leaving it is maintained during the linear down slope of two decades of the clearance curve, and that local blood flow can be calculated from washout rate constant obtained from this part of the curve. The method employing intramyocardial injection of Xenon‐133 was found to give the same results as atraumatic epicardial labelling indicating negligible effect of the injection trauma and supporting the validity of the local injection method using small volumes (2–10 μl).Keywords
This publication has 24 references indexed in Scilit:
- Distribution of Coronary Blood Flow in the Left Ventricular Wall of Dogs Evaluated by the Uptake of Xe‐133Acta Physiologica Scandinavica, 1977
- Shunting by Diffusion of Inert Gas in Skeletal MuscleActa Physiologica Scandinavica, 1972
- Washout of133Xenon after Intramuscular Injection and Direct Measurement of Blood Flow in Skeletal MuscleScandinavian Journal of Clinical and Laboratory Investigation, 1970
- Non‐Uniform Blood Flow in the Left Ventricular Wall of Dogs Measured by the Xe‐133 Wash‐out TechniqueActa Physiologica Scandinavica, 1969
- Inert Gas Diffusion Method for Measurement of Blood Flow Using Saturation TechniquesCirculation Research, 1968
- Regional Myocardial Blood Flow*Journal of Clinical Investigation, 1967
- Inert Gas Diffusion Method for Measurement of Blood FlowCirculation Research, 1967
- MEASUREMENTS OF NORMAL AND COLLATERAL CORONARY BLOOD FLOW BY CLOSE‐ARTERIAL AND INTRAMYOCARDIAL INJECTION OF KRYPTON85 AND XENON133Acta Physiologica Scandinavica, 1966
- Collateral Blood Flow in the Myocardium of Dogs Measured with Krypton85Acta Physiologica Scandinavica, 1964
- Muscle Blood Flow in Normal Man and in Patients with Intermittent Claudication Evaluated by Simultaneous Xe133 and Na24 Clearances *Journal of Clinical Investigation, 1964