Accessory equipment considerations with respect to MRI compatibility
- 1 January 1998
- journal article
- review article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 8 (1) , 12-18
- https://doi.org/10.1002/jmri.1880080107
Abstract
The MR Section of The National Electrical Manufacturers Association (NEMA), in response to a request from the Food & Drug Administration (FDA), recently issued a position paper to address generic issues related to the compatibility of accessory equipment produced by third party equipment manufacturers or MR equipment users and intended to be used in conjunction with MR equipment or within the MR scanning room. The recommendations concern scanning accessories, such as radiofrequency (RF) coils, patient monitoring equipment and injectors, as well as patient comfort accessories and positioning devices. The following issues related to safety performance are discussed: (a) the interaction of the equipment with the MR scanner, (b) interactions of the MR scanner with the equipment, and (c) potential safety hazards for patients and staff that can be posed by accessory equipment in the MR scan environment. The recommendations are based on combined input from NEMA member companies who manufacture MR systems and MR accessories and are presented for consideration in the design of MR accessory products and incorporation of these concepts into testing plans to ensure MR compatibility of third party devices.Keywords
This publication has 34 references indexed in Scilit:
- The role of magnetic susceptibility in magnetic resonance imaging: MRI magnetic compatibility of the first and second kindsMedical Physics, 1996
- Burns associated with the use of monitoring equipment during MR proceduresJournal of Magnetic Resonance Imaging, 1996
- Patient monitoring during clinical MR imaging.Radiology, 1992
- Monitoring heart rate and oxygen saturation with a fiber-optic pulse oximeter during MR imaging.American Journal of Roentgenology, 1992
- Use of Oximetry during MR Imaging of Pediatric PatientsRadiology, 1991
- Reduction of sound levels with antinoise in MR imaging.Radiology, 1989
- Severe burn of the finger caused by using a pulse oximeter during MR imagingAmerican Journal of Roentgenology, 1989
- Potential hearing loss resulting from MR imaging.Radiology, 1988
- Magnetic resonance imaging artifacts: mechanism and clinical significance.RadioGraphics, 1986
- Magnetic resonance imaging: Preliminary experience in orthopedic radiologyMagnetic Resonance Imaging, 1984