Comparative study of the elevation topography of complex shapes
- 1 June 1998
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 24 (6) , 741-750
- https://doi.org/10.1016/s0886-3350(98)80125-9
Abstract
To compare the accuracy and precision of the elevation topography from two commercially available instruments using videokeratoscopy or rasterstereography. University of Ottawa Eye Institute, Ottawa General Hospital, Ontario, Canada. Repeated measurements of elevation topography of six calibrated surfaces were done with the PAR Corneal Topography System (CTS) and the Tomey Topographic Modeling System (TMS-1). The shapes simulated normal (A: aspheric, B: spherocylindric) and postsurgical corneas (C: hyperopic, D: myopic, E: central island, F: phototherapeutic keratectomy). Surface shapes were described by parametric equations. Equation parameters associated with each elevation measurement were determined by best-fit analysis. Measurement precision was assessed by the standard deviation of the difference between the fitted and the measured data. Fitted parameters were compared with nominal values obtained from an independent calibration of each surface. The root mean square error (RMSE) of the deviation of the fitted from the nominal surfaces was used to evaluate the accuracy of each instrument. The accuracy of the CTS exceeded that of the TMS-1 for all surfaces measured. The RMSE values (micron) were (A: 0.1, 6.5), (B: 0.3, 3.8), (C: 1.1, 11.8), (D: 5.0, 43.0), (E: 1.2, 3.2) and (F: 2.2, 17.5) for the CTS and TMS-1, respectively. The differences in the measured data from the fit surface were generally smaller with the TMS-1. Quantitative analysis of elevation measurements showed that the CTS represented surface topography more accurately than the TMS-1.Keywords
This publication has 7 references indexed in Scilit:
- Corneal topography: A review of terms and conceptsJournal of Cataract & Refractive Surgery, 1996
- PAR Corneal Topography System (PAR CTS): The Clinical Application of Close-Range PhotogrammetryOptometry and Vision Science, 1995
- How Accurately Can Videokeratographic Systems Measure Surface Elevation?Optometry and Vision Science, 1995
- Assessment of the Power and Height of Radial Aspheres Reported by a Computer-assisted KeratoscopeAmerican Journal of Ophthalmology, 1995
- Analysis of the Inherent Error of the TMS-1 Topographic Modeling System in Mapping a Radially Aspheric SurfaceCornea, 1995
- Characterization of the Inherent Error in a Spherically-Biased Corneal Topography System in Mapping a Radially Aspheric Surface/Comment: Robert B. Mandell, OD, PhD Berkeley, Calif/Comment: Raymond A. Applegate, OD, PhD San Antonio, Tex/Response: Cynthia Roberts, PhDJournal of Refractive Surgery, 1994
- Accuracy and Precision of the Corneal Analysis System and the Topographic Modeling SystemCornea, 1992