The Wear of Cross-Linked Polyethylene against Itself
- 1 March 1996
- journal article
- review article
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
- Vol. 210 (1) , 11-16
- https://doi.org/10.1243/pime_proc_1996_210_386_02
Abstract
Cross-linked polyethylene (XLPE) may have an application as a material for an all-plastic surface replacement finger joint. It is inexpensive, biocompatible and can be injection-moulded into the complex shapes that are found on the ends of the finger bones. Further, the cross-linking of polyethylene has significantly improved its mechanical properties. Therefore, the opportunity exists for an all-XLPE joint, and so the wear characteristics of XLPE sliding against itself have been investigated. Wear tests were carried out on both reciprocating pin-on-plate machines and a finger function simulator. The reciprocating pin-on-plate machines had pins loaded at 10 N and 40 N. All pin-on-plate tests show wear factors from the plates very much greater than those of the pins. After 349 km of sliding, a mean wear factor of 0.46 × 10−6 mm3/N m was found for the plates compared with 0.021 × 10−6 mm3/N m for the pins. A fatigue mechanism may be causing this phenomenon of greater plate wear. Tests using the finger function simulator give an average wear rate of 0.22 ×10−6 mm3/N m after 368 km. This sliding distance is equivalent to 12.5 years of use in vivo. The wear factors found were comparable with those of ultra-high molecular weight polyethylene (UHMWPE) against a metallic counterface and, therefore, as the loads across the finger joint are much less than those across the knee or the hip, it is probable that an all-XLPE finger joint will be viable from a wear point of view.Keywords
This publication has 17 references indexed in Scilit:
- Metacarpophalangeal Joint Prostheses: A Review of past and Current DesignsProceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 1993
- Silicone SynovitisJournal of Hand Surgery (European Volume), 1993
- Wear and friction properties of prosthetic joint materials evaluated on a reciprocating pin-on-flat apparatusWear, 1993
- Macroscopic and microscopic wear mechanisms in ultra-high molecular weight polyethyleneWear, 1993
- The effect of transfer film and surface roughness on the wear of lubricated ultra-high molecular weight polyethyleneClinical Materials, 1993
- Wear of cross-linked polyethylene against itself: a material suitable for surface replacement of the finger jointJournal of Biomedical Engineering, 1991
- A Finger Function Simulator and the Laboratory Testing of Joint ReplacementsProceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 1990
- Three-dimensional geometric analysis of the metacarpophalangeal jointThe Journal of Hand Surgery, 1988
- RUFUS H. ALLDREDGE, M.D. 1908-1987Journal of Bone and Joint Surgery, 1988
- Flexible Implant Arthroplasty in the Rheumatoid Metacarpophalangeal JointClinics in Rheumatic Diseases, 1984