List-mode maximum-likelihood reconstruction applied to positron emission mammography (PEM) with irregular sampling
- 1 May 2000
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 19 (5) , 532-537
- https://doi.org/10.1109/42.870263
Abstract
We present a preliminary study of list-mode likelihood reconstruction of images for a rectangular positron emission tomograph (PET) specifically designed to image the human breast. The prospective device consists of small arrays of scintillation crystals for which depth of interaction is estimated. Except in very rare instances, the number of annihilation events detected is expected to be far less than the number of distinguishable events. If one were to histogram the acquired data, most histogram bins would remain vacant. Therefore, it seems natural to investigate the efficacy of processing events one at a time rather than processing the data in histogram format. From a reconstruction perspective, the new tomograph presents a challenge in that the rectangular geometry leads to irregular radial and angular sampling, and the field of view extends completely to the detector faces. Simulations are presented that indicate that the proposed tomograph can detect 8-mm-diameter spherical tumors with a tumor-to-background tracer density ratio of 3:1 using realistic image acquisition parameters. Spherical tumors of 4-mm diameter are near the limit of detectability with the image acquisition parameters used. Expressions are presented to estimate the loss of image contrast due to Compton scattering.Keywords
This publication has 10 references indexed in Scilit:
- Continuous Time Dynamic PET Imaging Using List Mode DataPublished by Springer Nature ,1999
- Reconstruction in PET cameras with irregular sampling and depth of interaction capabilityIEEE Transactions on Nuclear Science, 1998
- Fast accurate iterative three-dimensional Bayesian reconstruction for low-statistics positron volume imagingIEEE Transactions on Nuclear Science, 1998
- Fast accurate iterative reconstruction for low-statistics positron volume imagingPhysics in Medicine & Biology, 1998
- List-mode likelihood: EM algorithm and image quality estimation demonstrated on 2-D PETIEEE Transactions on Medical Imaging, 1998
- List-mode likelihoodJournal of the Optical Society of America A, 1997
- Algorithms to identify detector Compton scatter in PET modulesIEEE Transactions on Nuclear Science, 1996
- A Maximum a Posteriori Probability Expectation Maximization Algorithm for Image Reconstruction in Emission TomographyIEEE Transactions on Medical Imaging, 1987
- Image Reconstruction from List-Mode Data in an Emission Tomography System Having Time-of-Flight MeasurementsIEEE Transactions on Nuclear Science, 1983
- Analysis of Experiments in Particle PhysicsAnnual Review of Nuclear Science, 1964