Reduction of Space Charge Effects Using a Three-Aperture Gas Dynamic Vacuum Interface for Inductively Coupled Plasma-Mass Spectrometry
- 1 November 1994
- journal article
- research article
- Published by SAGE Publications in Applied Spectroscopy
- Vol. 48 (11) , 1367-1372
- https://doi.org/10.1366/0003702944028100
Abstract
A three-aperture gas dynamic vacuum interface for ICP-MS has been developed which reduces the ion current within the ion optics. The effect on performance limitations previously associated with space charge were determined. The gas and ion dynamics within the first stage of the vacuum interface are similar to those of current ICP-MS instruments and allow delineation of the relative effects of space charge in the interface region and within the ion optics. The sensitivity of the instrument to trace elements is similar to that of current commercial instruments. The instrument shows an improvement in the discrimination against low mass ion transmission. It also shows a dramatic improvement in both the magnitude and analyte-ion mass dependence of the signal suppression induced by a high concentration of a heavy concomitant element (Tl). The new design results in more uniform ion kinetic energies as a function of ion mass-to-charge ratio. The performance improvements are ascribed to the reduction of space charge effects resulting from both the reduction of the ion current within the ion optics and the reduction of the mass dependence of the ion kinetic energies. It is concluded that the discrimination against low-mass ions and the magnitude and analyte mass dependence of the signal suppression induced by concomitant heavy elements observed with current ICP-MS instruments derive from space charge effects within the ion optics. These effects are less significant within the first stage of the vacuum interface or within the mass analyzer.Keywords
This publication has 13 references indexed in Scilit:
- Space charge in ICP-MS: calculation and implicationsSpectrochimica Acta Part B: Atomic Spectroscopy, 1992
- Methods for the detection of single atoms using optical and mass spectrometry. Invited lectureJournal of Analytical Atomic Spectrometry, 1992
- Fundamental studies of the sampling process in an inductively coupled plasma mass spectrometer: III. Monitoring the ion beamSpectrochimica Acta Part B: Atomic Spectroscopy, 1991
- Fundamental studies of the sampling process in an inductively coupled plasma mass spectrometer-II: Ion kinetic energy measurementsSpectrochimica Acta Part B: Atomic Spectroscopy, 1991
- Electrical effects during the mass spectrometric sampling of ions from hot flame gases at atmospheric pressureInternational Journal of Mass Spectrometry and Ion Processes, 1991
- Fundamental studies of the sampling process in an inductively coupled plasma mass spectrometer-ISpectrochimica Acta Part B: Atomic Spectroscopy, 1991
- Nonspectroscopic interelement interferences in inductively coupled plasma mass spectrometryAnalytical Chemistry, 1988
- Gas dynamics of the inductively coupled plasma mass spectrometry interfaceJournal of Analytical Atomic Spectrometry, 1988
- Matrix-effect observations in inductively coupled plasma mass spectrometryJournal of Analytical Atomic Spectrometry, 1987
- Flow Properties of a Partially Ionized Free Jet ExpansionPhysics of Fluids, 1971