Abstract
Evaluation of thyroid status by measurement of free thyroid hormone concentrations seems particularly helpful in conditions with altered serum binding proteins. In pregnancy, a condition of increased thyroxine binding globulin, serum free thyroxine (FT4) and free triiodothyronine (FT3) concentrations have been reported to be normal, increased or decreased. In the present study we have measured serum total and free thyroid hormone concentrations in pregnant women, their newborns and nonpregnant women. Serum FT4 and FT3 concentrations have been measured with 10 different commercially available kits and the results obtained have been compared. Serum total thyroid hormone concentrations in pregnant women were significantly higher than in their newborns and in nonpregnant women. Maternal serum FT4 concentrations measured with the different kits were always significantly lower than values in nonpregnant women. Furthermore, with one kit, the mean maternal serum FT4 concentration was below the normal range and with many kits, a large number of maternal serum samples had serum FT4 concentrations below the normal range. With all kits, except two, neonatal serum FT4 concentrations were higher than values in their respective mothers and, in general, lower than values in nonpregnant women. Serum FT3 concentrations in nonpregnant women were in the normal range, except with one kit, in which the mean serum FT3 concentration was below the normal range. Serum FT3 concentrations in newborns resulted markedly lower than in parturient and in non pregnant women. With almost all kits, serum FT3 values were below the normal range in many maternal samples. With one kit, maternal serum FT3 concentrations resulted higher than in nonpregnant women, whereas with the other kits serum FT3 concentrations were lower. Despite the variability of serum FT4 and FT3 concentrasions, serum TSH concentrations in pregnant women and their newborns, resulted in the normal range. These findings suggest that many kits for the measurement of serum free thyroid hormone concentrations do not seem adequate to evaluate the real thyroid status of pregnant women and newborns. Therefore, in these physiological conditions the measurement by commercial kits of serum FT4 and FT3 concentrations do not offer a real advantage in respect to serum total thyroid hormone determination.Keywords
This publication has 52 references indexed in Scilit:
- Serum free thyroxine and free triiodothyronine concentrations in pregnancy.BMJ, 1983
- SERUM FREE THYROXINE CONCENTRATION AND FREE THYROID HORMONE INDICES IN NORMAL PREGNANCYClinical Endocrinology, 1983
- INTERPRETATION OF FREE THYROXINE RADIOIMMUNOASSAY DATAThe Lancet, 1982
- ARTIFACTUAL REDUCTION IN CIRCULATING FREE THYROXINE CONCENTRATION BY RADIOIMMUNOASSAYThe Lancet, 1982
- Thyroid-Pituitary InteractionNew England Journal of Medicine, 1982
- Thyroid Development and Disorders of Thyroid Function in the NewbornNew England Journal of Medicine, 1981
- LONGITUDINAL STUDY OR SERUM THYROID HORMONES, CHORIONIC GONADOTROPHIN AND THYROTROPHIN DURING AND AFTER NORMAL PREGNANCYClinical Endocrinology, 1979
- Measurements of free and total serum T3 and T4 in pregnant subjects and in neonatesThe Lancet Healthy Longevity, 1976
- CLINICAL APPLICATION OF SERUM-TOTAL-THYROXINE ESTIMATION, RESIN UPTAKE, AND FREE-THYROXINE INDEXThe Lancet, 1969
- A new method for measuring the free thyroid hormone in human serum and an analysis of the factors that influence its concentration.Journal of Clinical Investigation, 1965