Uncertainty contributions to species specific isotope dilution analysis. Part 2. Determination of methylmercury by HPLC coupled with quadrupole and multicollector ICP-MS
- 9 July 2003
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 18 (9) , 1039-1046
- https://doi.org/10.1039/b305454n
Abstract
Species-specific isotope dilution analysis (IDA) has been used to determine the mass fraction of methylmercury in a fish muscle certified reference material, DORM-2. Two spike solutions were prepared and their mass fractions determined by coupling high-performance liquid chromatography (HPLC) with both quadrupole (Q) and multicollector (MC) inductively coupled plasma mass spectrometry (ICP-MS) and uncertainty budgets calculated. For the Q-ICP-MS determination the relative standard uncertainty of the spike was 4.1%. The major uncertainty contribution (62%) arose from the uncertainties associated with the relative isotopic abundances of Hg isotopes as given by IUPAC. The measured isotope amount ratios (200Hg∶199Hg and 205Tl∶203Tl) contributed 37% of the combined uncertainty. For the multicollector instrument the relative standard uncertainty of the spike solution mass fraction was 0.7%. In this case the uncertainty budget was dominated by the Hg isotopic uncertainties, with a contribution of 99%. The uncertainty contributions from the measured isotope amount ratios were reduced to 0.7% of the total when using MC-ICP-MS. The two spike solutions were separately used to determine the mass fraction of methylmercury in DORM-2 CRM by species-specific IDA, using HPLC coupled with quadrupole ICP-MS. The values found were 4.45 ± 0.90 µg g−1 and 4.25 ± 0.47 µg g−1 using spikes characterised by Q- and MC-ICP-MS, respectively (the uncertainties quoted are the expanded uncertainty, k = 2), compared with a certified value of 4.47 ± 0.32. The major uncertainty contribution for each determination was from the measured isotope amount ratios (70%) with lesser contributions from the uncertainties associated with the natural isotopic abundance of Hg and the spike mass fraction.Keywords
This publication has 13 references indexed in Scilit:
- Instrument response functions, mass bias and matrix effects in isotope ratio measurements and semi-quantitative analysis by single and multi-collector ICP-MSJournal of Analytical Atomic Spectrometry, 2003
- Isotope Dilution ICP-MS for Speciation StudiesApplied Spectroscopy Reviews, 2003
- Orthodox uncertainty budgeting for high accuracy measurements by isotope dilution inductively coupled plasma-mass spectrometryAnalytica Chimica Acta, 2001
- Accurate analysis of selenium in water and serum using ETV-ICP-MS with isotope dilutionJournal of Analytical Atomic Spectrometry, 2000
- High-performance liquid chromatography–isotope dilution inductively coupled plasma mass spectrometry for speciation studies: an overviewTrAC Trends in Analytical Chemistry, 2000
- Comparison of different extraction techniques used for methylmercury analysis with respect to accidental formation of methylmercury during sample preparationChemosphere, 1999
- Estimation of uncertainties in ICP-MS analysis: a practical methodologyAnalytica Chimica Acta, 1999
- Letter to the Editor: Artifact formation of methylmercury in sediments.Analytical Chemistry, 1999
- Structured approach to achieving high accuracy measurements with isotope dilution inductively coupled plasma mass spectrometryJournal of Analytical Atomic Spectrometry, 1998
- Tutorial review. Calculating standard deviations and confidence intervals with a universally applicable spreadsheet techniqueThe Analyst, 1994