Although the electrocardiogram is known to be nondiagnostic within the bore of any high‐field magnet due to the magnetohydrodynamic effect, there are an increasing number of applications that require accurate electrocardiogram monitoring of a patient inside the MRI room but outside of the magnet bore. Magnetohydrodynamic effects on the ST segment of the electrocardiogram waveform were investigated in six subjects at magnetic field strengths ranging from 6.4 mT to 652 mT at the aortic midarch, and the electrocardiogram was found to be accurate at magnetic fields below 70 mT. This corresponds to a distance of 160 cm from the isocenter and 80 cm from the bore entrance for the 1.5‐T MRI system used in this study. These results can be translated to any MRI system, with knowledge of the fringe field. Accurate electrocardiogram monitoring is feasible in close proximity to the MRI magnet, such as during and after pharmacologic or exercise stress, or interventional or surgical procedures performed in the MRI room. Magn Reson Med, 2010.Keywords
This publication has 17 references indexed in Scilit:
- Simulation of Elevated T-Waves of an ECG Inside a Static Magnetic Field (MRI)IEEE Transactions on Biomedical Engineering, 2008
- Extraction of the magnetohydrodynamic blood flow potential from the surface electrocardiogram in magnetic resonance imagingMedical & Biological Engineering & Computing, 2008
- Cardiac function and myocardial perfusion immediately following maximal treadmill exercise inside the MRI roomJournal of Cardiovascular Magnetic Resonance, 2008
- Effects of Exercise and Respiration on Blood Flow in Total Cavopulmonary ConnectionCirculation, 2003
- Feasibility to detect severe coronary artery stenoses with upright treadmill exercise magnetic resonance imagingThe American Journal of Cardiology, 2003
- Novel real-time R-wave detection algorithm based on the vectorcardiogram for accurate gated magnetic resonance acquisitionsMagnetic Resonance in Medicine, 1999
- Recommendations for standardization and specifications in automated electrocardiography: bandwidth and digital signal processing. A report for health professionals by an ad hoc writing group of the Committee on Electrocardiography and Cardiac Electrophysiology of the Council on Clinical Cardiology, American Heart Association.Circulation, 1990
- Evaluation of age, gender, heart rate and blood pressure changes and exercise conditioning on Doppler measured aortic blood flow acceleration and velocity during upright treadmill testingThe American Journal of Cardiology, 1988
- The Corrected Orthogonal Electrocardiogram and Vectorcardiogram in 510 Normal Men (Frank Lead System)Circulation, 1964
- The normal Q-T intervalAmerican Heart Journal, 1962