A new biomechanical method for determination of static prosthetic alignment
Open Access
- 1 August 1997
- journal article
- research article
- Published by Wolters Kluwer Health in Prosthetics and Orthotics International
- Vol. 21 (2) , 107-113
- https://doi.org/10.3109/03093649709164538
Abstract
A new static alignment method for trans-tibial prostheses is suggested using the individual load line as a reference. Standing posture and static alignment of 18 experienced trans-tibial prosthetic users with good walking ability were determined and compared with 20 healthy persons. The individual load line was defined by means of the new Otto Bock alignment system “L.A.S.A.R. Posture”. The sagittal standing posture of trans-tibial amputees and non-amputees differs. Normally only a prosthesis worn by the trans-tibial amputee and dynamically aligned over an extended period of time satisfies biomechanical rules of alignment. In contrast, prostheses aligned during one session in the traditional subjective manner seem to lack any recognizable biomechanical systematics. Initial results suggest the knee centre should be 10 to 30mm behind the load line, depending on patient's weight. This knee position is independent on the type of the prosthetic foot.Keywords
This publication has 3 references indexed in Scilit:
- Four-bar linkage prosthetic knee mechanismsProsthetics and Orthotics International, 1994
- A force-line visualization systemProsthetics and Orthotics International, 1979
- Das Kniegelenk des Menschen als biomechanisches Problem - The human knee-joint as a biomechanical problemBiomedizinische Technik/Biomedical Engineering, 1977